15W Single Output Industrial DIN Rail Power Supply
DR-15 series
Features :
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
No load power consumption<0.5W
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DR-15-5
DR-15-12
DR-15-15
DR-15-24
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
CURRENT RANGE
RATED POWER
2.4A
0 ~ 2.4A
12W
1.25A
1A
0.63A
0 ~ 1.25A
0 ~ 1A
15W
0 ~ 0.63A
15.2W
15W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
120mVp-p
120mVp-p
13.5 ~ 16.5V
1.0%
150mVp-p
21.6 ~ 26.4V
1.0%
OUTPUT
10.8 ~ 13.2V
1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1000ms, 50ms/230VAC
1000ms, 50ms/115VAC at full load
70ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
INPUT
77%
84%
83.5%
85%
0.88A/115VAC
0.48A/230VAC
COLD START 35A/115VAC
65A/230VAC
105 ~ 160% rated output power
OVERLOAD
Note.5
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V
PROTECTION
27.6 ~ 32.4V
OVER VOLTAGE
Protection type : Shut off o/p voltage, clamping by zener diode
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
I/P-O/P:3KVAC
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 4)
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
EMC IMMUNITY
MTBF
1172.3K hrs min. MIL-HDBK-217F (25
25*93*56mm (W*H*D)
)
OTHERS
NOTE
DIMENSION
PACKING
0.1Kg; 140pcs/15Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Constant current operation region is within 60% ~100% rated output voltage. Protection type for short circuit is hiccup mode and will recover automatically
after fault condition is removed.
File Name:DR-15-SPEC 2011-06-17