10W DC-DC Regulated Dual Output Converter
DKE10 series
Features :
2:1 wide input range
4:1 wide input range(option)
1000VDC I/O isolation
3000VDC I/O isolation(option)
Built-in EMI filter
Protections: Short circuit / Overload
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Approvals: FCC / CE
2 years warranty
SPECIFICATION
ORDER NO.
DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C- DKE10A- DKE10B- DKE10C-
05
5V
100 ~ 1000mA
10W
05
05
12
12
12
15
15
15
24
24
24
DC VOLTAGE
12V
15V
24V
CURRENT RANGE
RATED POWER
42 ~ 420mA
60mVp-p
33.3 ~ 333mA
60mVp-p
21 ~ 210mA
80mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p
OUTPUT
LINE REGULATION
LOAD REGULATION
VOLTAGE ACCURACY
Note.3 0.3%
Note.4 0.5%
2.0%
SWITCHING FREQUENCY
VOLTAGE RANGE
250KHz min.
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 72VDC
78% 81% 82% 80% 80%
Full load A: 1100mA B: 530mA C: 270mA
83%
80%
82%
82%
81%
85%
80%
EFFICIENCY (Typ.)
DC CURRENT
INPUT
No load A: 30mA
Pi network
B: 16mA
C: 8mA
FILTER
Fuse recommended
PROTECTION
160% ~ 250% rated output power
OVER CURRENT
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
PROTECTION
(Note. 5)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +71 (Refer to output load derating curve)
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-25 ~ +105 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:1KVDC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 Class B, FCC part 15 Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
EMS IMMUNITY
MTBF
)
OTHERS
DIMENSION
50.8*25.4*11.2mm or 2"*1"*0.44" inch (L*W*H)
32g
WEIGHT
Pin Configuration
Derating Curve
Mechanical Specification
Unit: mm
11.27
50.8
Pin No.
Output
15.3
20.3
100
80
1
2
3
4
5
+Vin
-Vin
3
1
2
+Vout
COM
-Vout
4
5
BOTTOM VIEW
5.8
1.0 + 0.2/-0.1
-25
0
25
50 60 71
100
Ta (
)
1.All parameters are specified at normal input, rated load, 25 70% RH Ambient.
NOTE
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:DKE10-SPEC 2008-05-20