VDE
MINIATURE POWER RELAY
DK-RELAYS
20
.787
12.5
.492
FEATURES
20
.787
15
.591
• Large capacity in small size: 10 A 250 V AC (1a)
10
.394
10
.394
• High sensitivity: 200 mW nominal operating power
• High breakdown voltage 4,000 Vrms between contacts and
coil 1,000 Vrms between open contacts Meeting FCC Part 68
• Sealed construction
1a
1a1b
• Latching types available
mm inch
SPECIFICATIONS
Contact
Characteristics
2 Form A,
1 Form A
1 Form B
Max. operating speed
Initial insulation resistance*1
Between open
20 cpm (at rated load)
Arrangement
1 Form A
Min. 1,000 mΩ (at 500 V DC)
1,000 Vrms
4,000 Vrms
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Initial
contacts
30 mΩ
breakdown
Between contacts
voltage*2
Contact material
Gold flash over silver alloy
and coil
Nominal
switching capacity
10 A 250 V AC
10 A 30 V DC
8 A 250 V AC
8 A 30 V DC
Surge voltage between coil and
contact*3
Min. 10,000 V
Max. switching
power
Operate time*4
(at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
300 W, 2,500 VA 240 W, 2,000 VA
Max. 10 ms (Approx. 5 ms)
Max. 8 ms (Approx. 3 ms)
Rating
(resistive)
Max. switching
voltage
250 V AC,
30 V DC
250 V AC,
30 V DC
Max. switching
current
Temperature rise
(at nominal voltage)
Max. 40°C with nominal coil voltage
10 A
8 A
and at 10 A switching current
Mechanical
5×107
Functional*5
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
88.2 m/s2 {9 G}, 10 to 55 Hz
at double amplitude of 1.5 mm
Shock
Expected
life (min.
operations)
105
105
Destructive*6
Functional*7
resistance
Electrical
(resistive)
(10 A 250 V AC,
10 A 30 V DC)
(8 A 250 V AC,
8 A 30 V DC)
Vibration
Coil
176.4 m/s2 {18 G}, 10 to 55 Hz
at double amplitude of 3.0 mm
resistance
Destructive
Nominal operating power
200 mW
Conditions for oper- Ambient
ation, transport and temp.
storange*8
–40°C to +65°C
–40°F to +149°F
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10 mA
(Not freezing and
condensing at low
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Humidity
5 to 85% R.H.
temperature)
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
1 Form A
Unit
Approx. 5.6 g .20 oz
Approx. 6 g .21 oz
*7 Detection time: 10µs
1 Form A 1 Form B,
weight
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
2 Form A
TYPICAL
ORDERING INFORMATION
APPLICATIONS
• Switching power supply
• Power switching for various
OA equipment
• Control or driving relays for industrial
machines (robotics, numerical control
machines, etc.)
• Output relays for programmable logic
controllers, temperature controllers,
timers and so on.
Ex. DK
1a
L2
12V
Contact arrangement
Operating function
Coil voltage
1a: 1 Form A
2a: 2 Form A
Nil: Single side stable
L2: 2 coil latching
3, 5, 6, 9, 12, 24V
1a1b: 1 Form A 1 Form B
Note: Standard packing Carton: 50 pcs.; Case: 500 pcs.
UL/CSA, TÜV approved type is standard.
• Home appliances
239