Applicable standard
Operating
Storage
Temperature range
Storage
-40 C to +105C (Note1)
-10 C to +60C (Note3)
Temperature range
Operating
Rating
20% to 80% (Note2)
40% to 70% (Note3)
Humidity range
Applicable
Connectors
Applicable
Contact
Humidity range
UL,C-UL
Rating
Voltage
Current
DF65-7P-1.7V(##)
50 V AC/DC
24 AWG : 3.5A
26 AWG : 2.5A
28 AWG : 2.0A
1
DF65-2428SCF(##)
DF65-2428SCFA(##)
Voltage
Current
50 V AC/DC
24 AWG : 3.5A
26 AWG : 2.0A
28 AWG : 2.0A
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
100 V DC.
100 M MIN.
-
-
X
X
500 V AC for 1 min.
No flashover or breakdown.
Voltage proof
Mechanical characteristics
Tin plated : 30 times insertion and extraction.
Mechanical operation
No damage, crack or looseness of parts.
-
X
Gold plated : 50 times insertion and extraction.
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Vibration
Shock
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Insulation resistance: 100 M MIN.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1~2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +105℃
Time 30min→ 30min
Under 5 cycles.
(The transferring time of the tank is 2~3 min)
(After leaving the room temperature for 1~2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB. After mounted on PCB, operating temperature
and humidity range are applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
1
△
1
DIS-H-00004782
SN.MIWA
SZ.ONO
20190416
20140716
20140715
20140715
20140715
Remarks
Approved
Checked
Designed
Drawn
KI.AKIYAMA
HK.UMEHARA
TT.OHSAKO
TT.OHSAKO
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC4-354320-00
DF65-7S-1.7C
CL666-6015-1-00
Part No.
Specification sheet
HIROSE ELECTRIC CO., LTD.
1
△
1/1
Code No.