Applicable standard
Operating
Storage
Temperature range
-55 C to +105C (Note1)
-10 C to +60C (Note3)
Temperature range
Operating
Humidity range
Storage
Humidity range
Voltage
Rating
1
20% to 80% (Note2)
40% to 70% (Note3)
Applicable connector
Applicable contact
DF63SF-3S-3.96C
630V AC/DC
DF63SF-1618SCFA(##)
Current
AWG#16 : 15 A/pin
AWG#18 : 13 A/pin
1
Rated Voltage
600V AC/DC
300V AC/DC
Rated Current
See above
See above
Overvoltage Category
IP-Degree
UL,C-UL
TÜV
-
-
IP00
Ⅱ
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
Marking
X
Electric characteristics
10 m MAX.
Contact resistance
-
-
-
20mV MAX, 1mA (DC or 1000Hz).
X
X
X
500 V DC.
1000 M MIN.
Insulation resistance
Voltage proof
2200 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
50 times insertion and extraction.
1) Contact resistance: 20 mΩ MAX.
2) No damage, crack or looseness of parts.
-
X
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
1) No electrical discontinuity of 1μs.
-
-
-
X
X
X
2) No damage, crack or looseness of parts.
490 m/s2 duration of pulse 11 ms at 3 times each for 1) No electrical discontinuity of 1μs.
3 both axial directions.
Measured by applicable connector.
2) No damage, crack or looseness of parts.
Insertion force : 20.0 N MAX
Extraction force : 1.0 N MIN
Mating force
Environmental characteristics
Damp heat
(Steady state)
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
(After leaving the room temperature for 1 to 2h.)
1) Contact resistance: 20 mΩ MAX.
2) Insulation resistance: 500 MΩ Min.
3) No damage, crack or looseness of parts.
1) Contact resistance: 20 mΩ MAX.
2) Insulation resistance: 1000 MΩ Min.
3) No damage, crack or looseness of parts.
-
-
X
X
Rapid change of
temperature
Temperature -55℃→ +105℃
Time
30min→ 30min
Under 5 cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2h.)
Exposed at +105℃,96h.
Dry heat
Cold
1) Contact resistance: 20 mΩ MAX.
2) Insulation resistance: 1000 MΩ Min.
3) No damage, crack or looseness of parts.
1) Contact resistance:20 mΩ MAX.
2) Insulation resistance: 1000 MΩ Min.
3) No damage, crack or looseness of parts.
-
-
X
X
Exposed at -55℃,96h.
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the condition of long term storage for unused products before mount on pcb,
After mounted on pcb, operating temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
1
2
DIS-H-00006130
TS.MIYAKI
SZ.ONO
20200730
20170123
20170123
20170123
20170123
△
Remarks
Approved
Checked
Designed
Drawn
HS.OKAWA
YN.TAKASHITA
SANGMUK.LIM
SANGMUK.LIM
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Specification sheet
Drawing No.
ELC-374749-52-00
Part No.
DF63SF-2P-7.92TV(52)
1
CL680-0704-0-52
△
1/2
HIROSE ELECTRIC CO., LTD.
Code No.
FORM HD0011-2-1