Applicable standard
Operating
range
temperature
Storage
temperature range
Storage
Humidity range
Voltage
-55 c to +105c (Note1)
20% to 80% (Note2)
DF63SF-*S-3.96C
-10 c to +60c (Note3)
Operating
Rating
40% to 70% (Note3)
Humidity range
Applicable
connector
AC/DC 630V
Applicable cable
Current
15A(2PIN,P=7.92mm)
AWG#16 to 18
AWG#16
12A(3PIN,P=3.96mm)
13A(2PIN,P=7.92mm)
10A(3PIN,P=3.96mm)
Insulation
Diameter
Φ2.1 to 2.7 mm
AWG#18
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
10 m MAX.
-
20mV MAX, 1mA (DC or 1000Hz).
X
Mechanical characteristics
Contact insertion
And extraction
Forces
Insertion force
Extraction force 0.3 N MIN.
4.5 N MAX.
□0.8±0.002 mm by steel gauge.
X
X
-
-
Mechanical operation
50 times insertion and extraction.
①Contact resistance: 20 mΩ MAX.
②No damage, crack or looseness of parts.
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for 3 both
axial directions.
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Contact resistance: 20 mΩ MAX.
-
-
X
X
(steady state)
(After leaving the room temperature for
1 to 2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +105℃
Time 30min→ 30min
Under 5 cycles.
(the transferring time of the tank is 2 to 3 min)
(after leaving the room temperature for 1 to 2h.)
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the condition of long term storage for unused products before harness assembly.
After harness assembly, operation temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
0
△
Remarks
Approved
Checked
Designed
Drawn
HS.OKAWA
20191112
20191112
20191112
20191112
SZ.ONO
TO.KUROMATSU
SK.CHIBA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification test AT:Assurance test X:applicable test
Drawing No.
ELC-367036-00-00
DF63SF-1618SCFA
Part No.
Specification sheet
1/1
Hirose electric co., Ltd.
0
△
Code No.
CL680-0703-0-00
FORM HD0011-2-1