Applicable standard
Operating Temperature Range
-40 to +105 C (Note 1)
Storage Temperature Range
Storage Humidity Range
-10 C to +60 C (Note 3)
40 % to 70 % (Note 3)
DF63-6S-3.96C
Rating
Operating Humidity Range
20% to 80% (Note 2)
Voltage
Current
630 V AC/DC
AWG 16 : 10A
AWG 18 : 8A
AWG 20 : 7A
AWG 22 : 6A
Applicable Connector
Applicable Contact
DF63-1618PC*
DF63-2022PC*
Rated Voltage
600V AC/DC
Rated Current
See above
Overvoltage Category
-
IP-Degree
-
1
1
UL,C-UL
TÜV
300V AC/DC
See above
IP00
Ⅱ
Specifications
Test method
Item
Requirements
QT AT
Construction
General Examination
X
X
X
X
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
Marking
Electric Characteristics
Insulation Resistance
Voltage Proof
X
X
-
-
500 V DC.
1000 M MIN.
1500 V AC for 1 min.
No flashover or breakdown.
Mechanical Characteristics
X
X
-
-
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude 0.75 mm, at
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
10 cycles for 3 direction.
Acceleration 490 m/s2 duration of pulse 11 ms at 3
times for 3 directions.
Environmental Characteristics
Damp Heat
Exposed at 40 ± 2 C , humidity 90 to 95 %, 96 h.
1.Insulation resistance: 500 M MIN.
2.No damage, crack or looseness of parts.
X
X
-
-
(Steady State)
(After leaving the room temperature for 1 to 2 h.)
Rapid Change Of
Temperature
Temperature -55 C → +85 C
Time
1.Insulation resistance: 1000 M MIN.
2.No damage, crack or looseness of parts.
30 min → 30 min
Under 5 Cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2 h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB board , operating temperature and humidity range is applied for interim storage during transportation.
DATE
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
SZ.ONO
1
△
20180925
20151026
20151026
20151026
20151026
2
DIS-H-00004236
TS.KUMAZAWA
APPROVED
CHECKED
DESIGNED
DRAWN
KI.AKIYAMA
TS.FUKUSHIMA
YK.YAMAGUCHI
HK.HAYASHI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-365920-00-00
DF63A-6EP-3.96C
DRAWING NO.
SPECIFICATION SHEET
PART NO.
CODE NO.
1/1
HIROSE ELECTRIC CO., LTD.
CL680-0558-0-00
1
△