Applicable standard
Operating
Storage
-55 to +105℃(Note1)
-10 C to +60C (Note3)
Rating Temperature Range
Operating
Temperature Range
Storage
20% to 80% (Note2)
630 V AC/DC
40% to 70% (Note3)
Humidity Range
Humidity Range
Voltage
Current
Applicable Connector
AWG #16 : 10A AWG #18 : 8A Applicable Contact
AWG #20 : 7A AWG #22 : 6A
DF63-4S-3.96C
DF63-1618PC*
DF63-2022PC*
IP-Degree
Rated Voltage
600V AC/DC
Rated Current
See above
Overvoltage Category
-
-
1
1
UL,C-UL
TÜV
300V AC/DC
See above
IP00
Ⅱ
Specifications
Test method
Item
Requirements
QT AT
Construction
General Examination
X
X
X
X
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
Marking
Electric Characteristics
Insulation Resistance
Voltage Proof
X
X
-
-
500 V DC.
1000 M MIN.
1500 V AC for 1 min.
No flashover or breakdown.
Mechanical Characteristics
X
X
-
-
Mechanical operation
30 times insertion and extraction
No damage, crack or looseness of parts.
Vibration
Frequency 10 to 55 Hz, single amplitude 0.75 mm, at
10 cycles for 3 direction.
Shock
Acceleration 490 m/s2 duration of pulse 11 ms at 3
X
-
times for 3 directions.
Environmental Characteristics
Damp Heat
1.Insulation resistance: 500 M MIN.
2.No damage, crack or looseness of parts.
X
X
Exposed at 40 ± 2℃ , humidity 90 to 95 %, 96 h.
-
-
(Steady State)
(After leaving the room temperature for 1 to 2h.)
Rapid Change Of
Temperature
1.Insulation resistance: 1000 M MIN.
2.No damage, crack or looseness of parts.
Temperature -55℃→ +85℃
Time
30min→ 30min
Under 5 Cycles.
(The transferring time of the tank is 2 to 3 MIN)
(After leaving the room temperature for 1 to 2h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB board , operating temperature and humidity range is applied for interim storage during transportation.
Date
Count
Description of revisions
Designed
Checked
1
△
20180925
20170126
20170126
20170126
20170126
2
DIS-H-00004236
TS.KUMAZAWA
SZ.ONO
Approved
Checked
Designed
Drawn
HS.OKAWA
TS.FUKUSHIMA
YK.YAMAGUCHI
YK.YAMAGUCHI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-365660-00-00
DF63A-4EP-3.96C
Drawing No.
Specification sheet
Part No.
Code No.
1/1
Hirose electric co., ltd.
CL680-0556-0-00
1
△
FORM HD0011-2-1