Applicable standard
Operating
Storage
-55 to +105℃ (Note1)
-10C to +60C (Note3)
Temperature Range
Temperature Range
Storage
Operating
20% to 80% (Note2)
40% to 70% (Note3)
Humidity Range
Humidity Range
Rating
Voltage
Current
630V AC/DC
Applicable Connector
Applicable Contact
DF63-3S-3.96C
DF63-1618PC(F)(A)
DF63-2022PC(F)(A)
AWG 16 : 12A/pin
AWG 18 : 10A/pin
AWG 20 : 8A/pin
AWG 22 : 7A/pin
Rated Voltage
600V AC/DC
Rated Current
See above
Overvoltage Category
IP-Degree
-
UL,C-UL
-
TÜV
300V AC/DC
See above
IP00
Ⅱ
Specifications
Test method
Item
Requirements
QT AT
Construction
General Examination
Marking
X
X
X
X
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
Electric Characteristics
Insulation Resistance
Voltage Proof
X
X
-
-
500V DC.
1000 M MIN.
1500V AC for 1 min.
No flashover or breakdown.
Mechanical Characteristics
Mechanical Operation
X
X
-
-
30 times insertion and extraction.
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude 0.75 mm, at
10 cycles for 3 direction.
Acceleration 490 m/s2 duration of pulse 11 ms at 3
X
-
No damage, crack or looseness of parts.
times for 3 directions.
Environmental Characteristics
Damp Heat
1) Insulation resistance: 500 M MIN.
2) No damage, crack or looseness of parts.
X
X
Exposed at 40 ± 2 ℃ , humidity 90 to 95 %, 96 h.
-
-
(Steady State)
(After leaving the room temperature for 1 to 2 h.)
Rapid Change Of
Temperature
1) Insulation resistance: 1000 M MIN.
2) No damage, crack or looseness of parts.
Temperature -55℃ → +85℃
Time
1
30min → 30min
Under 5 Cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2 h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to unused product on packaged condition.
DATE
COUNT
1
DESCRIPTION OF REVISIONS
DESIGNED
TS.KUMAZAWA
CHECKED
1
△
20210826
DIS-H-00010586
SZ.ONO
Unless otherwise specified, refer to IEC 60512.
20210825
SJ.OKAMURA
SZ.ONO
APPROVED
CHECKED
DESIGNED
DRAWN
20210825
20210825
20210824
TS.KUMAZAWA
TS.HONJO
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-361667-00-00
DF63A-3EP-3.96C
DRAWING NO.
SPECIFICATION SHEET
PART NO.
CODE NO.
1/1
HIROSE ELECTRIC CO., LTD.
CL0680-0534-2-00
1
△
FORM HD0011-2-1