Applicable standard
Operating
temperature range
-40 C to +105C (Note1)
20% to 80% (Note2)
-10 C to +60C (Note3)
40% to 70% (Note3)
DF63-*S-3.96C
Contact
AWG 16
15A
AWG 18
13A
Current
Operating
Rating
1
2
humidity range
Storage
temperature range
Storage
14A
12A
3
4
5
6
12A
10A
10A
10A
10A
8A
humidity range
Applicable connector
Voltage
AC/DC
630V
8A
8A
Rated Voltage
600V AC/DC
300V AC/DC
Rated Current
See above
See above
Overvoltage Category
-
IP-Degree
UL,C-UL
TÜV
-
IP00
Ⅱ
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
10 m MAX.
-
20mV MAX, 1mA (DC or 1000Hz).
X
Insulation resistance
Voltage proof
500 V DC.
1000 M MIN.
-
-
X
X
1500 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
50 times insertion and extraction.
①Contact resistance: 20 mΩ MAX.
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
-
-
-
X
X
X
Vibration
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
Shock
490 m/s2 duration of pulse 11 ms at 3 times each for 3 both
axial directions.
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Contact resistance: 20 mΩ MAX.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1-2h.)
②Insulation resistance: 500 M MIN.
③No damage, crack or looseness of parts.
①Contact resistance: 20 mΩ MAX.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
②Insulation resistance: 1000 M MIN.
③No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2h.)
1)Solder bath method
Soldered at solder temperature
260c for in immersing duration 10s.
2)Manual soldering
Resistance to
soldering heat
Such as impaired function ,no deformation of case
of excessive looseness of the terminals.
1
1
X
X
-
-
Soldering iron temperature :300℃
Soldering time :3s
No strength on contact.
Solderability
Remarks
Soldered at solder temperature
245c for in immersing duration 5 s.
A new uniform coating of solder shall cover
minimum of 95 of the surface being immersed.
Note :Include the temperature rising by current.
Note2:No condensing
Note3:Apply to the condition of long term storage for unused products befor PCB on board. After PCB on board, operating temperature and humiditty range is
applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
1
△
2
DIS-H-00005354
TO.KUROMATSU
SZ.ONO
20191008
20161028
20161028
20161028
20161028
Approved
Checked
Designed
Drawn
TS.FUKUSHIMA
TS.FUKUSHIMA
YK.YAMAGUCHI
YK.YAMAGUCHI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-359864-01-00
DF63-*P-3.96DS(01)
Part No.
Specification sheet
1
△
1/1
Hirose electric co., ltd.
Code No.
CL680-