Applicable standard
Operating
Current
-55 C to +105C (Note1)
20% to 80% (Note2)
-10 C to +60C (Note3)
40% to 70% (Note3)
3
△
Contact
AWG 16:
15A
AWG 18
13A
12A
10A
8A
temperature range
Operating
Rating
1
2
3
4
5
6
Humidity range
Storage
range
temperature
14A
Storage
Humidity range
12A
Applicable connector
Applicable contact
DF63-*P-3.96DS*
DF63-1618SC*
10A
10A
8A
Voltage
AC/DC
630V
10A
8A
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
10 m MAX.
20mV MAX, 1mA (DC or 1000Hz).
-
-
-
X
X
X
Insulation resistance
Voltage proof
500 V DC.
1000 M MIN.
1500 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
30 times insertion and extraction.
Mechanical operation
①Contact resistance: 20 mΩ MAX.
-
-
-
X
X
X
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
Vibration
490 m/s2 duration of pulse 11 ms at 3 times each for 3 both
axial directions.
Shock
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Contact resistance: 20 mΩ MAX.
②Insulation resistance: 500 M MIN
③No damage, crack or looseness of parts.
①Contact resistance: 20 mΩ MAX.
②Insulation resistance: 1000 M MIN
③No damage, crack or looseness of parts.
-
-
X
X
(steady state)
(After leaving the room temperature for 1 - 2h.)
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
Under 5 cycles.
(The transferring time of the tank is 2 - 3 min)
(After leaving the room temperature for 1 - 2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before PCB on board. After PCB on board, operating temperature
and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
3
△
1
DIS-H-00002332
MI.SAKIMURA
TS.FUKUSHIMA
KI.AKIYAMA
OM.MIYAMOTO
TO.HORII
16.11.29
13.09.11
13.09.10
13.09.10
13.09.10
REMARKS
Approved
Checked
Designed
Drawn
Unless otherwise specified, refer to IEC 60512.
TO.HORII
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-354067-00-00
DF63-*S-3.96C
Part no.
Specification sheet
Hirose electric co., ltd.
3
△
1/1
Code no.
CL680-
FORM HD0011-2-1