Applicable standard
Operating
Storage
Temperature range
-55 C to +105C (Note1)
-10 C to +60C (Note2)
40% to 70% (Note2)
Temperature range
Operating
Humidity range
Storage
Humidity range
Rating
20% to 80%
Voltage
Voltage
・
UL
250
V
AC/DC
29.9
V
AC/DC
C-UL
Rating
Current
Current
AWG 20 : 4 A/pin AWG 22 : 3A/pin
AWG 24 : 2 A/pin AWG 26 : 1 A/pin
4A/pin
Operating
temperature
range
Applicable
Connector
DF62W-9S-2.2C(##)
-55
C
to +75 C (Note1)
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
Marking
X
Electric characteristics
30 m MAX.
Contact resistance
-
-
-
20mV MAX, 1mA (DC or 1000Hz).
X
X
X
500 V DC.
1000 M MIN.
Insulation resistance
Voltage proof
650 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
30 times insertion and extraction.
1)Contact resistance: 30 mΩ MAX.
2)No damage, crack or looseness of parts.
-
X
Vibration
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
1)No electrical discontinuity of 1μs.
2)No damage, crack or looseness of parts.
-
-
-
-
X
X
X
X
Shock
Mating force
Measured by applicable connector.
Insertion force : 33.7 N MAX
Extraction force : 1.75 N MIN
30 N MIN
Lock strength
Measured by applicable connector.
Environmental characteristics
Damp heat
(Steady state)
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
(After leaving the room temperature for 1 to 2h.)
1)Contact resistance: 30 mΩ MAX.
2)Insulation resistance: 500 MΩ Min.
3)No damage, crack or looseness of parts.
1)Contact resistance: 30 mΩ MAX.
2)Insulation resistance: 1000 MΩ Min.
3)No damage, crack or looseness of parts.
-
-
X
X
Rapid change of
temperature
Temperature -55℃→ +105℃
Time
30min→ 30min
Under 5 cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2h.)
Exposed at +105℃,96h.
Dry heat
Cold
-
-
X
X
Exposed at -55℃,96h.
Remarks
Note 1: Include the temperature rising by current.
Note 2: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB, operation temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
2
△
1
DIS-H-00006308
HT.SATO
SZ.ONO
20200901
20180227
20180227
20180227
20180227
Unless otherwise specified, refer to IEC 60512.
Approved
Checked
Designed
Drawn
HS.OKAWA
TS.FUKUSHIMA
HT.SATO
SN.MIWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-379591-20-00
Part No.
DF62WZ-9P-2.2DSA(20)
Specification sheet
2
CL544-1050-0-20
△
1/2
HIROSE ELECTRIC CO., LTD.
Code No.
FORM HD0011-2-1