Applicable standard
Operating
Storage
Temperature range
Storage
Humidity range
Voltage
-40 C to +105C (Note1)
-10 C to +60C (Note3)
Temperature range
Operating
Humidity range
Applicable connector
Rating
20% to 80%(Note2)
40% to 70% (Note3)
1) DF62W-*EP-2.2C(##)
2) DF62WC-*EP-2.2C(##)
250V AC/DC
Applicable cable
Applicable
connector
Current
3
AWG 22 : 4A/pin
AWG 24 : 3.5A/pin
AWG 26 : 3A/pin
△
UL1007 AWG#22 to 24
UL1430 AWG#24 to 26
UL1061 AWG#24 to 26
1)
2)
Applicable
Insulation diameter
Applicable
connector
1)
2)
φ1.4 to 1.6mm
φ0.98 to 1.2mm
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
30 m MAX.
-
20mV MAX, 1mA (DC or 1000Hz).
X
Mechanical characteristics
Mechanical operation
30 times insertion and extraction.
1)Contact resistance: 30 mΩ MAX.
-
-
-
X
X
X
2)No damage, crack or looseness of parts.
1)No electrical discontinuity of 1μs.
2)No damage, crack or looseness of parts.
1)No electrical discontinuity of 1μs.
2)No damage, crack or looseness of parts.
Vibration
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Shock
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
1)Contact resistance: 30 mΩ MAX.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1-2h.)
2)No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
1)Contact resistance: 30 mΩ MAX.
2)No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the packaged and unused product.
3
△
Count
Description of revisions
Designed
HT.SATO
Checked
Date
3
△
2
DIS-H-00015722
SZ.ONO
20221017
20131114
20131114
20131114
20131114
Approved
Checked
Designed
Drawn
OM.MIYAMOTO
OM.MIYAMOTO
TO.HORII
TO.HORII
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-353516-00-00
DF62W-EP2226PCF
Part No.
Specification sheet
3
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
CL0544-1001-4-00
△
FORM HD0011-2-1