Applicable standard
Operating
Storage
Temperature range
Storage
-40 C to +105C (Note1)
-10 C to +60C (Note3)
Temperature range
Operating
Rating
20% to 80% (Note2)
40% to 70% (Note3)
Humidity range
Humidity range
Applicable connector
Applicable cable
Voltage
Current
DF62W-*EP-2.2C(##)
AC/DC
250V
UL3443
UL1007
AWG#20(Insulation diameterφ1.53mm)
AWG#22(Insulation diameterφ1.58mm)
AWG#20: 5 A
AWG#22: 4 A
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
20mV MAX, 1mA (DC or 1000Hz).
30 m MAX.
-
X
Mechanical characteristics
30 times insertion and extraction.
Mechanical operation
①Contact resistance: 30 mΩ MAX.
-
-
-
X
X
X
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
①No electrical discontinuity of 1μs.
②No damage, crack or looseness of parts.
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
Vibration
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Shock
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Contact resistance: 30 mΩ MAX.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1 - 2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
①Contact resistance: 30 mΩ MAX.
②No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2 - 3 min)
(After leaving the room temperature for 1 - 2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB, operation temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
0
△
Remarks
Approved
Checked
Designed
Drawn
HS.OKAWA
17.06.07
17.06.07
17.06.06
17.06.06
TS.FUKUSHIMA
HT.SATO
Unless otherwise specified, refer to IEC 60512.
MI.SAKIMURA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-360862-00-00
DF62W-EP2022PC
Part No.
Specification sheet
HIROSE ELECTRIC CO., LTD.
0
△
1/1
Code No.
CL544-1018-7-00
FORM HD0011-2-1