Applicable standard
Operating
Storage
temperature range
Storage
-40 C to +105C (Note1)
20% to 80% (Note2)
DF62W-9EP-2.2C(##)
-10 C to +60C (Note3)
temperature range
Operating
Rating
40% to 70% (Note3)
humidity range
Applicable
humidity range
Voltage
AC/DC
250V
connector
Applicable contact
Current
AWG 20 : 3.5A
AWG 22 : 3A
AWG 24 : 2A
AWG 26 : 1A
DF62W-2022SC*
DF62W-2226SC*
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
500 V DC.
1000 M MIN.
No flashover or breakdown.
-
-
X
X
650 V AC for 1 min.
Voltage proof
Mechanical characteristics
30 times insertion and extraction.
Mechanical operation
No damage, crack or looseness of parts.
-
X
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Vibration
Shock
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Insulation resistance: 1000 MΩ Min.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1-2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
①Insulation resistance: 1000 MΩ Min.
②No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3:Apply to the condition of long term storage for unused products before pcb on board after pcb board , operating temperature and humidity range is applied
for interm storage during transportation.
Count
Description of revisions
Designed
Checked
Date
0
△
Remarks
Approved
Checked
Designed
Drawn
KI.AKIYAMA
TS.FUKUSHIMA
YK.YAMAGUCHI
MI.SAKIMURA
15.10.21
15.10.21
15.10.21
15.10.21
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-353729-11-00
DF62W-9S-2.2C(11)
Part No.
Specification sheet
HIROSE ELECTRIC CO., LTD.
0
△
1/1
Code No.
CL544-1010-5-11
FORM HD0011-2-1