Applicable standard
Operating
Storage
temperature range
Storage
humidity range
Voltage
-40 C to +105C (Note1)
20% to 80% (Note2)
DF62W-2EP-2.2C(##)
-10 C to +60C (Note3)
temperature range
Operating
Rating
40% to 70% (Note3)
humidity range
Applicable
connector
AC/DC
250V
Applicable contact
Current
AWG20 : 5A/pin
AWG22 : 4A/pin
AWG24 : 3.5A/pin
AWG26 : 3A/pin
DF62W-2022SC*
DF62W-2226SC*
1
△
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
500 V DC.
1000 M MIN.
No flashover or breakdown.
-
-
X
X
Voltage proof
650 V AC for 1 min.
Mechanical characteristics
Mechanical operation
30 times insertion and extraction.
No damage, crack or looseness of parts.
-
X
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
1)Insulation resistance: 1000 MΩ Min.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1-2h.)
2)No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
Under 5 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the packaged and unused product.
1
△
Count
Description of revisions
Designed
HT.SATO
Checked
Date
1
2
DIS-H-00015658
SZ.ONO
20221014
20151021
20151021
20151021
20151021
△
Remarks
Approved
Checked
Designed
Drawn
KI.AKIYAMA
TS.FUKUSHIMA
YK.YAMAGUCHI
MI.SAKIMURA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Specification sheet
Drawing No.
ELC-353517-11-00
DF62W-2S-2.2C(11)
Part No.
1
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
CL0544-1002-7-11
△
FORM HD0011-2-1