Applicable standard
Operating
Storage
Temperature range
Storage
-35 C TO +105C (NOTE1)
20% TO 80% (NOTE2)
DF62B-13EP-2.2C(##)
-10 C TO +60C (NOTE3)
Temperature range
Operating
Rating
40% TO 70% (NOTE3)
Humidity range
Applicable
Humidity range
Voltage
AC/DC
250V
Connector
Voltage
Current
UL・
C-UL
Rating
250
V
AC/DC
AWG 22 : 3A/pin
AWG 24 : 2A/pin
AWG 26-30 : 1A/pin
Current
:
:
AWG 22
AWG 24
AWG 26-30 :1A/pin
3A/pin
2A/pin
1
Operating
Temperature
range
Applicable contact
DF62-22SC*
DF62-2428SC*
DF62-30SC*
-35 C TO +75C (NOTE1)
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
Marking
X
Electric characteristics
Insulation resistance
500 V DC.
1000 M MIN.
-
-
X
X
650 V AC for 1 min.
No flashover or breakdown.
Voltage proof
Mechanical characteristics
30 times insertion and extraction.
Mechanical operation
No damage, crack or looseness of parts.
-
X
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms at 3 times each for
3 both axial directions.
Vibration
Shock
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
-
-
X
X
Environmental characteristics
Damp heat
Exposed at 40 ± 2℃ , 90 to 95 %, 96 h.
①Insulation resistance: 1000 M MIN.
-
-
X
X
(Steady state)
(After leaving the room temperature for 1-2h.)
②No damage, crack or looseness of parts.
Rapid change of temperature Temperature -55℃→ +85℃
Time 30min→ 30min
①Insulation resistance: 1000 M MIN.
②No damage, crack or looseness of parts.
Under 5 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before inserting terminal. After inserting terminal, operating temperature
and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
1
△
1
DIS-H-00019419
RI.GENDA
SZ.ONO
20231115
20140606
20140606
20140606
20140606
Remarks
Approved
Checked
Designed
Drawn
KI.AKIYAMA
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
ELC-351976-18-02
DF62C-13S-2.2C(18)
Part No.
Specification sheet
HIROSE ELECTRIC CO., LTD.
1
△
1/1
Code No.
CL0544-0571-7-18
FORM HD0011-2-1