APPLICABLE STANDARD
OPERATING TEMPERATURE
RANGE
STORAGE
TEMPERATURE RANGE
STORAGE
-35 C TO +105C (NOTE1)
20% TO 80% (NOTE2)
DF62B-2EP-2.2C(##)
-10 C TO +60C (NOTE3)
OPERATING
RATING
40% TO 70% (NOTE3)
HUMIDITY RANGE
APPLICABLE
HUMIDITY RANGE
VOLTAGE
AC/DC
250V
CONNECTOR
VOLTAGE
CURRENT
CURRENT
UL・
C-UL
RATING
250
V
AC/DC
AWG 22
AWG 24
: 4A/pin
: 2A/pin
:
:
AWG 22
AWG 24
3A/pin
2A/pin
AWG 26-30 :1A/pin
AWG 26-30 : 1A/pin
DF62-22SC*
1
OPERATING
TEMPERATURE
RANGE
APPLICABLE
CONTACT
-35 C TO +75C (NOTE1)
DF62-2428SC*
DF62-30SC*
SPECIFICATIONS
ITEM
TEST METHOD
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
MARKING CONFIRMED VISUALLY.
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
X
X
X
X
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
30 m MAX.
20mV MAX, 1mA (DC or 1000Hz).
500 V DC.
650 V AC FOR 1 min.
-
-
-
X
X
X
INSULATION RESISTANCE
VOLTAGE PROOF
1000 M MIN.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
30 TIMES INSERTION AND EXTRACTION.
①CONTACT RESISTANCE: 30 mΩ MAX.
-
-
-
X
X
X
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①NO ELECTRICAL DISCONTINUITY OF 1μs.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①NO ELECTRICAL DISCONTINUITY OF 1μs.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 10 CYCLES FOR 3 DIRECTION.
VIBRATION
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES EACH
FOR 3 BOTH AXIAL DIRECTIONS.
SHOCK
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2℃ , 90 TO 95 %, 96 h.
①CONTACT RESISTANCE: 30 mΩ MAX.
②INSULATION RESISTANCE: 1000 M MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①CONTACT RESISTANCE: 30 mΩ MAX.
②INSULATION RESISTANCE: 1000 M MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
-
-
X
X
(STEADY STATE)
(AFTER LEAVING THE ROOM TEMPERATURE FOR
1~2h.)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
TIME
30min→ 30min
UNDER 5 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2~3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1~2h.)
NOTE 1: INCLUDE THE TEMPERATURE RISING BY CURRENT.
NOTE2:NO CONDENSING
NOTE3:APPLY TO THE CONDITION OF LONG TERM STORAGE FOR UNUSED PRODUCTS BEFOR PCB ON BOARD, AFTER PCB ON BOARD,
OPERATING TEMPERATURE AND HUMIDITTY RANGE IS APPLIED FOR INTERIM STRAGE DURING TRANSPORTATION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
1
△
1
DIS-H-00019315
RI.GENDA
SZ.ONO
20231030
20130911
20130911
20130911
20130906
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
KI.AKIYAMA
OM.MIYAMOTO
TH.YOSHIZAWA
MI.SAKIMURA
Unless otherwise specified, refer to JIS C 5402.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-351955-18-02
DF62B-2S-2.2C(18)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1
△
1/1
CL0544-0551-0-18
FORM HD0011-2-1