APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
STORAGE
-35 C TO +105C (NOTE1)
-10 C TO +60C (NOTE3)
TEMPERATURE RANGE
OPERATING
RATING
20% TO 80% (NOTE2)
DF62B-24EP-2.2C(##)
40% TO 70% (NOTE3)
HUMIDITY RANGE
APPLICABLE
HUMIDITY RANGE
VOLTAGE
AC/DC
250V
CONNECTOR
VOLTAGE
CURRENT
UL・
C-UL
RATING
:
:
AWG 22
AWG 24
AWG 26-30
2.5A
2A
250
V
AC/DC
2
CURRENT
:
:
AWG 22
AWG 24
AWG 26-30
3A
2A
1A
:
1A
APPLICABLE
CONTACT
:
DF62-22SC*
DF62-2428SC*
DF62-30SC*
OPERATING
TEMPERATURE
RANGE
-35 C TO +75C (NOTE1)
SPECIFICATIONS
ITEM
TEST METHOD
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
MARKING CONFIRMED VISUALLY.
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
X
X
X
X
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
30 m MAX.
20mV MAX, 1mA (DC or 1000Hz).
500 V DC.
650 V AC FOR 1 min.
-
-
-
X
X
X
INSULATION RESISTANCE
VOLTAGE PROOF
1000 M MIN.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
30 TIMES INSERTION AND EXTRACTION.
①CONTACT RESISTANCE: 30 mΩ MAX.
-
-
-
X
X
X
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①NO ELECTRICAL DISCONTINUITY OF 1μs.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①NO ELECTRICAL DISCONTINUITY OF 1μs.
②NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 10 CYCLES FOR 3 DIRECTION.
VIBRATION
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES EACH
FOR 3 BOTH AXIAL DIRECTIONS.
SHOCK
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2℃ , 90 TO 95 %, 96 h.
①CONTACT RESISTANCE: 30 mΩ MAX.
②INSULATION RESISTANCE: 1000 M MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
①CONTACT RESISTANCE: 30 mΩ MAX.
②INSULATION RESISTANCE: 1000 M MIN.
③NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
-
-
X
X
(STEADY STATE)
(AFTER LEAVING THE ROOM TEMPERATURE FOR
1-2h.)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
TIME
30min→ 30min
UNDER 5 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
REMARKS
NOTE 1: INCLUDE THE TEMPERATURE RISING BY CURRENT.
NOTE 2:NO CONDENSING
NOTE 3:APPLY TO THE CONDITION OF LONG TERM STORAGE FOR UNUSED PRODUCTS BEFORE PCB ON BOARD, AFTER PCB BOARD ,
OPERATING TEMPERATURE AND HUMIDITY RANGE IS APPLIED FOR INTERIM STORAGE DURING TRANSPORTATION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
2
△
1
DIS-H-00019309
RI.GENDA
SZ.ONO
20231023
20130911
20130911
20130911
20130906
REMARKS
APPROVED
CHECKED
DESIGNED
DRAWN
KI.AKIYAMA
OM.MIYAMOTO
TH.YOSHIZAWA
MI.SAKIMURA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-348670-18-02
DF62B-24S-2.2C(18)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
2
△
1/1
CL0544-0539-4-18
FORM HD0011-2-1