APPLICABLE STANDARD
Operating
temperature range
RATING Operating
Humidity range
Current
Storage
-55C TO + 105C (NOTE 1)
-10C TO + 60C (NOTE 3)
Temperature range
Storage
20% TO 80% (NOTE 2)
40% TO 70% (NOTE 3)
DF60FS(R)-2S-10.16C(##)
Humidity range
Applicable
Crimp socket
AWG8
45A/pin
35A/pin
AWG10
AWG12
28A/pin
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
MECHANICAL CHARACTERISTICS
Vibration
Frequency 10 to 500 HZ, single amplitude 0.75 mm, No damage, crack or looseness of parts.
at 10 cycles, for 3 directions.
X
X
-
-
Shock
490 m/s2 duration of pulse 11 ms at 3 times for 3
directions.
No damage, crack or looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Damp heat
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
X
X
(steady state)
Rapid change of
temperature
-
-
Temperature -55℃→ +105℃
Time
30min→ 30min
Under 25 cycles.
(the transferring time of the tank is 2-3 min)
(after leaving the room temperature for 1-2h.)
Dry heat
No damage, crack or looseness of parts.
No damage, crack, or looseness of parts
Exposed at 105 ± 2℃, 250h
(after leaving the room temperature for 1-2h.)
-
-
X
Cold
X
Exposed at -55±3c, 96h
Remarks
Note 1:Include the temperature rising by current.
Note 2:No condensing.
Note 3:Apply to the unused and packaged product.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△0
Unless otherwise specified , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
SJ.OKAMURA
20231019
20231019
20231018
20231018
TT.OHSAKO
KT.NUMATA
SK.CHIBA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-402082-00-00
DF60FS-2S-10.16C-CV
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL0680-4014-0-00
FORM HD0011-2-1