Applicable standard
Operating
Storage
-55C to + 105C (Note 1)
-10C to + 60C (Note 3)
temperature range
temperature range
Storage
humidity range
Operating
Rating
humidity range
20% to 80% (Note 2)
40% to 70% (Note 3)
Current (*1)
AWG8
AWG10
AWG12
45A/pin
35A/pin
28A/pin
Applicable
contact
Voltage
DF60-8PC(F)A(##)
DF60-1012PC(F)A(##)
1000V AC/DC
Rated voltage
Rated current
Overvoltage category
IP- degree
2
AWG8:65A/pin,AWG10:55A/pin,AWG12:40A/pin
UL
600V AC/DC
―
―
(At ambient temp.25℃)(Note 5)
C-UL
600V AC/DC
600V AC/DC
See above(*1)(Temp. rise up 30℃MAX)
―
Ⅲ
―
TÜV
See above(*1)
IP20(Note 7)
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
1000V DC.
1000M MIN.
X
X
-
-
3000V AC for 1 min.
No flashover or breakdown.
Voltage proof
Mechanical characteristics
Frequency 10 to 500 Hz, total amplitude 1.5 mm, acceleration No damage, crack or looseness of parts.
of 98 m/s2, at 2 h, for 3 directions.
Vibration
X
X
X
-
-
-
490 m/s2 duration of pulse 11 ms at 3 times for 3 directions. No damage, crack or looseness of parts.
Shock
49N MIN
Contact extraction force
Pull out the cable after housing fixation.
Environmental characteristics
Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts.
1)
2)
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
Damp heat
X
X
(Steady state)
Rapid change of
temperature
-
-
Insulation resistance: 1000M MIN.
1)
2)
Temperature -55℃→ +105℃
Time 30min→ 30min
No damage, crack or looseness of parts
Under 25 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Exposed at 105 ± 2℃, 250h
Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts
1)
2)
Dry heat
Cold
-
-
X
X
(After leaving the room temperature for 1-2h.)
Insulation resistance: 1000M MIN.
1)
Exposed at -55 ± 3℃, 96h
2) No damage, crack or looseness of parts
Remarks
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the unused product on packaged condition.
Count
Description of revisions
Designed
TS.KUMAZAWA
Checked
Date
2
△
1
DIS-H-00018494
SZ.ONO
20230616
20220214
20220214
Unless otherwise specifid , refer to IEC 60512.
Approved
Checked
Designed
Drawn
SJ.OKAMURA
TT.OHSAKO
SN.MIWA
SN.MIWA
20220210
20220210
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-386591-00-00
DF60FR-2EP-10.16C
Part no.
Specification sheet
Hirose electric co., ltd.
2
△
1/2
Code no.
CL0680-4012-0-00
FORM HD0011-2-1