APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
-55C TO + 105C (NOTE 1)
TEMPERATURE RANGE
STORAGE
-10C TO + 60C (NOTE 3)
OPERATING
RATING
HUMIDITY RANGE
CURRENT(*1)
HUMIDITY RANGE
APPLICABLE
CONTACT
20% TO 80% (NOTE 2)
40% TO 70% (NOTE 3)
DF60-8PC(F)A(##)
DF60-1012PC(F)A(##)
1000V AC/DC
AWG8
42A
34A
28A
AWG10
AWG12
VOLTAGE
Rated voltage
Rated current
Overvoltage category
IP- degree
AWG8:55A/AWG10:50A/AWG12:40A
(AT AMBIENT TEMP.25℃)(NOTE 5)
See above(*1)(Temp. rise up 30℃MAX)
See above(*1)
UL
600V AC/DC
―
―
C-UL
600V AC/DC
600V AC/DC
―
Ⅲ
―
TÜV
IP20 (Note 7)
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
ELECTRIC CHARACTERISTICS
INSULATION
1000V DC.
1000M MIN.
X
X
-
-
RESISTANCE
VOLTAGE PROOF
3000V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
VIBRATION
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
X
-
SHOCK
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
DIRECTIONS.
X
-
X
-
Contact extraction force
Pull out the cable after housing fixation.
49N MIN
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF
PARTS.
X
X
(STEADY STATE)
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +105℃
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF
PARTS.
TIME
30min→ 30min
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRY HEAT
Cold
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
-
-
X
X
Exposed at -55±3C, 96h
① Contact resistance:
2m MAX.
② Insulation resistance: 1000M MIN.
③ No damage, crack or looseness of parts
Remarks
Note 1:Include the temperature rising by current.
Note2:No condensing
Note3:Apply to the condition of long term storage for unused products before mount on pcb,
After mounted on pcb, operating temperature and humidity range is applied for interim storage during transportation.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
Unless otherwise specified , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
ST.WADA
18.03.16
18.03.16
18.03.13
18.03.13
TT.OHSAKO
TT.OHSAKO
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-379272-00-00
DF60F-3EP-10.16C
PART NO.
CODE NO.
SPECIFICATION SHEET
0
△
1/2
HIROSE ELECTRIC CO., LTD.
CL680-4003-0-00
FORM HD0011-2-1