Applicable standard
Operating
Storage
temperature range
Storage
humidity range
Current (*1)
-55C to + 105C (Note 1)
-10C to + 60C (Note 3)
temperature range
Operating
Rating
20% to 80% (Note 2)
40% to 70% (Note 3)
humidity range
Applicable connector
DF60F-2S-10.16C(##)
DF60-*SCFA(##)
1000V AC/DC
AWG 8:45 A/pin
AWG10:35 A/pin
AWG12:28 A/pin
Voltage
3
Rated voltage
Rated current
Overvoltage category
IP- degree
UL
600V AC/DC
65A MAX/pin (At ambient temp.25℃)(Note 5)
―
―
C-UL
600V AC/DC
600V AC/DC
See above(*1)(Temp. rise up 30℃MAX)
―
Ⅲ
―
TÜV
See above(*1)
IP20
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
DC6V MAX, 1A
2m MAX.
X
-
Millivolt level method
1000V DC.
1000MΩMIN.
Insulation resistance
Voltage proof
X
-
3000V AC for 1 min.
No flashover or breakdown.
X
-
Mechanical characteristics
30 times insertions and extractions.
1) Contact resistance:
2m MAX.
Mechanical operation
X
X
X
2) No damage, crack or looseness of parts.
-
-
-
Frequency 10 to 500 Hz, total amplitude 1.5 mm, acceleration 1) No electrical discontinuity of 1s.
Vibration
of 98 m/s2, at 2 h, for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times for 3 directions.
2) No damage, crack or looseness of parts.
1) No electrical discontinuity of 1s.
Shock
2) No damage, crack or looseness of parts.
Environmental characteristics
Contact resistance:
Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts.
Contact resistance:
Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts
2m MAX.
1)
2)
3)
1)
2)
3)
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
Damp heat
X
X
(Steady state)
-
-
2m MAX.
Temperature -55℃→ +85℃
Time 30min→ 30min
Rapid change of
temperature
Under 25 cycles.
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Exposed at 105 ± 2℃, 250h
Contact resistance:
Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts
2m MAX.
1)
2)
3)
Dry heat
Cold
-
-
X
(After leaving the room temperature for 1-2h.)
Contact resistance:
Insulation resistance: 1000M MIN.
2m MAX.
1)
2)
Exposed at -55 ± 3℃, 96h
X
X
3) No damage, crack or looseness of parts
1)Solder bath method
Such as impaired function ,no deformation of case of
excessive looseness of the terminals.
Resistance to soldering
heat
Solder temperature : 260℃ for
Immersion,duration : 10 sec .
2)Manual soldering
-
-
Soldering iron temperature : 350±10℃
Soldering time : 5 sec.
No strength on contact.
Soldered at solder temperature,
Solder shall cover a minimum of
95 of the surface being immersed.
Solderability
Remarks
X
245 c for insertion duration, 5sec.
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the unused product on packaged condition.
Count
Description of revisions
Designed
TS.KUMAZAWA
Checked
Date
3
△
1
DIS-H-00018494
SZ.ONO
20230616
20220214
20220214
Unless otherwise specifid , refer to IEC 60512.
Approved
Checked
Designed
Drawn
SJ.OKAMURA
TT.OHSAKO
SN.MIWA
SN.MIWA
20220210
20220210
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-386586-50-00
DF60F-2P-10.16DSA(50)
Part no.
Specification sheet
Hirose electric co., ltd.
3
△
1/2
Code no.
CL0680-4007-0-50
FORM HD0011-2-1