APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO + 105C (NOTE 1)
20% TO 80% (NOTE 2)
1000V AC/DC
-10C TO + 60C (NOTE 3)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE
HUMIDITY RANGE
OPERATING
RATING
40% TO 70% (NOTE 3)
DF60-*EP-10.16C(##)
DF60R-*EP-10.16C
HUMIDITY RANGE
APPLICABLE
CONNECTOR
VOLTAGE
APPLICABLE
CABLE
CURRENT
AWG8
50A
AWG 8
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
DC6V MAX, 1A
2m MAX.
X
-
MILLIVOLT LEVEL METHOD
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
30TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
2m MAX.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
X
-
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, ① NO ELECTRICAL DISCONTINUITY OF 1s.
VIBRATION
SHOCK
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 ① NO ELECTRICAL DISCONTINUITY OF 1s.
X
X
X
-
-
-
DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
APPLY WIRE TENSIKE STRENGTH TO CAULKING AREA
AXIALLY UNTIL WIRE BECOME LOOSEN OR
BREAKDOWN
CLIMP TENSILE
STRENGTH
AWG8 : 401N MIN
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① CONTACT RESISTANCE:
2m MAX.
X
X
(STEADY STATE)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
-
-
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
① CONTACT RESISTANCE:
2m MAX.
TIME
30min→ 30min
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRY HEAT
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
① CONTACT RESISTANCE:
2m MAX.
-
X
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
REMARKS
NOTE 1:INCLUDING THE TEMPERATURE RISE BY CURRENT.
NOTE2:NO CONDENSING
NOTE3:APPLY TO THE CONDITION OF LONG TERM STORAGE FOR UNUSED PRODUCTS BEFORE PCB ON BOARD. AFTER PCB BOARD ,
OPERATING TEMPERATURE AND HUMIDITY RANGE IS APPLIED FOR INTERIM STORAGE DURING TRANSPORTATION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
Unless otherwise specifid , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
16.06.21
16.06.21
16.06.21
16.06.21
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-367007-00-00
DF60A-8PCFA
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL680-3057-0-00
FORM HD0011-2-1