APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO +105C (NOTE 1)
-10C TO +60C (NOTE 3)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE
HUMIDITY RANGE
APPLICABLE
CABLE
OPERATING
RATING
20% TO 80% (NOTE 2)
1000V AC/DC
40% TO 70% (NOTE 3)
HUMIDITY RANGE
VOLTAGE
AWG8 TO AWG12
DF60-8PC(F)A(07)
DF60-1012PC(F)A(07)
DF60A-8PC(F)A
APPLICABLE
CONTACT
CURRENT(*1)
AWG8
AWG10
AWG12
42A
33A
27A
RATED VOLTAGE
RATED CURRENT
OVERVOLTAGE CATEGORY
IP- DEGREE
AWG8:55A/AWG10:45A/AWG12:35A
UL
600V AC/DC
―
―
(AT AMBIENT TEMP.25℃)(NOTE 5)
C-UL
TUV
600V AC/DC
600V AC/DC
SEE ABOVE(*1)(TEMP. RISE UP 30℃MAX)
―
Ⅲ
―
SEE ABOVE(*1)
IPOO
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
INSULATION
1000V DC.
1000M MIN.
X
X
-
-
RESISTANCE
VOLTAGE PROOF
3000V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, ① NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
VIBRATION
X
X
-
-
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 ① NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
SHOCK
DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
X
X
(STEADY STATE)
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
TIME
30min→ 30min
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRY HEAT
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
-
X
Remarks
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB board , operating temperature and humidity range is applied for interim storage during transportation.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
Unless otherwise specifid , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
17.09.28
17.09.28
17.09.28
17.09.28
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-378021-00-00
DF60A-4EP-10.16C
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/4
CL680-3069-0-00
FORM HD0011-2-1