APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO + 105C (NOTE 1)
-10C TO + 60C (NOTE 3)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE
RATING
OPERATING
20% TO 80% (NOTE 2)
40% TO 70% (NOTE 3)
HUMIDITY RANGE
HUMIDITY RANGE
CURRENT(*1)
AWG8
AWG10
AWG12
50A
40A
31A
APPLICABLE
CONTACT
DF60-8SC(F)A
DF60-1012SC(F)A
1000V AC/DC
VOLTAGE
RATED VOLTAGE
RATED CURRENT
OVERVOLTAGE CATEGORY
IP- DEGREE
AWG8:65A/AWG10:55A/AWG12:45A
UL
600V AC/DC
―
―
(AT AMBIENT TEMP.25℃)(NOTE 5)
C-UL
TUV
600V AC/DC
600V AC/DC
SEE ABOVE(*1)(TEMP. RISE UP 30℃MAX)
―
Ⅲ
―
SEE ABOVE(*1)
IPOO
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
INSULATION
1000V DC.
1000M MIN.
X
X
-
-
RESISTANCE
VOLTAGE PROOF
3000V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
VIBRATION
X
X
-
-
SHOCK
DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
X
X
(STEADY STATE)
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
TIME
30min→ 30min
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRY HEAT
① INSULATION RESISTANCE: 1000M MIN.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
-
X
Remarks
Note 1:Include the temperature rising by current.
Note2:No condensing
Note3:Apply to the condition of long term storage for unused products before mount on pcb,
After mounted on pcb, operating temperature and humidity range is applied for interim storage during transportation.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
Unless otherwise specified , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
17.03.29
17.03.29
17.03.29
17.03.29
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-374734-15-00
DF60A-1S-10.16C(15)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/4
CL680-3058-0-15
FORM HD0011-2-1