APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO + 105C (NOTE 1)
20% TO 80% (NOTE 2)
1000V AC/DC
-10C TO + 60C (NOTE 3)
40% TO 70% (NOTE 3)
DF60(R)-*S-10.16C(##)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE
humidity range
Operating
RATING
humidity range
APPLICABLE
CONNECTOR
APPLICABLE
CABLE
VOLTAGE
CURRENT(*1)
2
AWG8
50A
AWG 8
RATED VOLTAGE
RATED CURRENT
OVERVOLTAGE CATEGORY
IP- DEGREE
2
AWG8:65A(AT AMBIENT TEMP.25℃)
UL
600V AC/DC
―
―
(NOTE 5)
C-UL
TUV
600V AC/DC
600V AC/DC
SEE ABOVE(*1)(TEMP. RISE UP 30℃MAX)
―
Ⅲ
―
SEE ABOVE(*1)
IPOO
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
DC6V MAX, 1A
2m MAX.
X
X
-
MILLIVOLT LEVEL METHOD
MECHANICAL CHARACTERISTICS
CONTACT INSERTION
AND EXTRACTION
FORCES
INSERTION FORCE
EXTRACTION FORCE
12.0 N MAX.
2.0 N MIN.
1.0±0.002 BY STEEL GAUGE.
-
MECHANICAL
30TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
2m MAX.
OPERATION
② NO DAMAGE, CRACK OR LOOSENESS
X
-
OF PARTS.
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, ① NO ELECTRICAL DISCONTINUITY OF 1s.
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 ① NO ELECTRICAL DISCONTINUITY OF 1s.
VIBRATION
SHOCK
X
X
X
-
-
-
DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
APPLY WIRE TENSIKE STRENGTH TO CAULKING AREA
AXIALLY UNTIL WIRE BECOME LOOSEN OR
BREAKDOWN
CLIMP TENSILE
STRENGTH
AWG8
401N MIN
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① CONTACT RESISTANCE:
2m MAX.
X
X
(STEADY STATE)
-
-
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
① CONTACT RESISTANCE:
2m MAX.
TIME
30min→ 30min
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRAY HEAT
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
① CONTACT RESISTANCE:
2m MAX.
-
X
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
Remarks
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the condition of long term storage for unused products before PCB on board .
After mounted on PCB board , operating temperature and humidity range is applied for interim storage during transportation.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
2
△
4
DIS-H-00002440
TS.KUMAZAWA
TS.FUKUSHIMA
KI.AKIYAMA
17.01.06
11.08.30
11.08.30
Unless otherwise specifid , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
OM.MIYAMOTO
SZ.ONO
SZ.ONO
11.08.30
11.08.30
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC4-336566-00
DF60-8SCFA
CL680-3003-2-00
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
2
△
1/3
FORM HD0011-2-1