APPLICABLE STANDARD
OPERATING
STORAGE
-55C TO + 105C (NOTE 1)
20% TO 80% (NOTE 2)
1000V AC/DC
-10C TO + 60C (NOTE 3)
TEMPERATURE RANGE
TEMPERATURE RANGE
STORAGE
HUMIDITY RANGE
OPERATING
RATING
40% TO 70% (NOTE 3)
DF60-*EP-10.16C(##)
DF60R-*EP-10.16C
HUMIDITY RANGE
APPLICABLE
CONNECTOR
VOLTAGE
APPLICABLE
CABLE
CURRENT(*1)
RATED VOLTAGE
AWG8
50A
AWG 8
RATED CURRENT
OVERVOLTAGE CATEGORY
IP- DEGREE
AWG8:65A(AT AMBIENT TEMP.25℃)
UL
600V AC/DC
―
―
(NOTE 5)
C-UL
TUV
600V AC/DC
600V AC/DC
SEE ABOVE(*1)(TEMP. RISE UP 30℃MAX)
―
Ⅲ
―
SEE ABOVE(*1)
IPOO
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
DC6V MAX, 1A
2m MAX.
X
-
MILLIVOLT LEVEL METHOD
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
30TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
2m MAX.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
X
-
FREQUENCY 10 TO 500 Hz, TOTAL AMPLITUDE 1.5 mm, ① NO ELECTRICAL DISCONTINUITY OF 1s.
VIBRATION
SHOCK
Acceleration of 98 m/s2, AT 2 h, FOR 3 DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3 ① NO ELECTRICAL DISCONTINUITY OF 1s.
X
X
X
-
-
-
DIRECTIONS.
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS..
APPLY WIRE TENSILE STRENGTH TO CAULKING AREA
AXIALLY UNTIL LOOSEN OR BROKEN.
CRIMP TENSILE
STRENGTH
300N MIN
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① CONTACT RESISTANCE:
2m MAX.
X
X
(STEADY STATE)
-
-
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55℃→ +85℃
① CONTACT RESISTANCE:
2m MAX.
TIME
30min→ 30min
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
UNDER 25 CYCLES.
(THE TRANSFERRING TIME OF THE TANK IS 2-3 min)
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
DRY HEAT
EXPOSED AT 105 ± 2℃, 250h
(AFTER LEAVING THE ROOM TEMPERATURE FOR 1-2h.)
① CONTACT RESISTANCE:
2m MAX.
-
X
② NO DAMAGE, CRACK OR LOOSENESS OF PARTS.
Remarks
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the condition of long term storage for unused products before PCB on board .
After mounted on PCB board , operating temperature and humidity range is applied for interim storage during transportation.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
Unless otherwise specifid , refer to IEC 60512.
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
17.02.07
17.02.07
17.02.07
17.02.07
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-345696-07-00
DF60-8PCA(07)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/3
CL680-3048-0-07
FORM HD0011-2-1