Applicable standard
Operating
Storage
-55C to + 105C (Note 1)
-10C to + 60C (Note 3)
temperature range
temperature range
Storage
humidity range
Operating
Rating
humidity range
20% to 80% (Note 2)
DF60A-3S-10.16C
DF60-*SCFA
40% to 70% (Note 3)
42 A
Applicable connector
2
Current(*1)
Voltage
1000V AC/DC
Rated voltage
Rated current
Overvoltage category
IP- degree
UL
600V AC/DC
600V AC/DC
600V AC/DC
55A(At ambient temp.25℃)(Note 5)
See above(*1)(Temp. rise up 30℃MAX)
See above(*1)
―
―
Ⅲ
―
―
C-UL
TÜV
IPOO
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
According to drawing.
X
X
X
X
Marking
Confirmed visually.
Electric characteristics
Contact resistance
Millivolt level method
DC6V MAX, 1A
2m MAX.
X
X
X
-
-
-
Insulation resistance
1000V DC.
1000M MIN.
Voltage proof
3000V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
① Contact resistance:
2m MAX.
Mechanical operation
30 times insertions and extractions.
X
X
X
② No damage, crack or looseness of parts.
-
-
-
Frequency 10 to 500 Hz, total amplitude 1.5 mm, acceleration ① No electrical discontinuity of 1s.
Vibration
of 98 m/s2, at 2 h, for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times for 3 directions.
② No damage, crack or looseness of parts.
① No electrical discontinuity of 1s.
Shock
② N o damage, crack or looseness of parts.
Environmental characteristics
Damp heat
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
① Contact resistance:
2m MAX.
X
X
(Steady state)
-
-
② Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts.
③
Temperature -55℃→ +85℃
Rapid change of
temperature
① Contact resistance:
2m MAX.
Time
30min→ 30min
② Insulation resistance: 1000M MIN.
Under 25 cycles.
No damage, crack or looseness of parts
③
(The transferring time of the tank is 2-3 min)
(After leaving the room temperature for 1-2h.)
Dry heat
Exposed at 105 ± 2℃, 250h
(After leaving the room temperature for 1-2h.)
① Contact resistance:
2m MAX.
-
-
X
X
② Insulation resistance: 1000M MIN.
No damage, crack or looseness of parts
③
Such as impaired function ,no deformation of
①Solder bath method
2
Resistance to soldering
heat
Solder temperature : 260℃ for
Immersion,duration : 10 sec .
②Manual soldering
case of excessive looseness of the terminals.
2
Soldering iron temperature : 350±10℃
Soldering time : 5 sec.
No strength on contact.
Soldered at solder temperature,
Solder shall cover a minimum of
95 of the surface being immersed.
Solderability
Remarks
X
245 c for insertion duration, 5sec.
-
Note1: Include the temperature rising by current.
Note2: No condensing.
Note3: Apply to the condition of long term storage for unused products before mount on pcb,
After mounted on pcb, operating temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
Designed
Checked
Date
2
△
4
DIS-H-00005429
TS.MIYAKI
SZ.ONO
20191028
20160405
20160405
Unless otherwise specifid , refer to IEC 60512.
Approved
Checked
Designed
Drawn
KI.AKIYAMA
TS.FUKUSHIMA
TS.KUMAZAWA
TS.KUMAZAWA
20160405
20160405
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-342145-27-00
DF60-3P-10.16DS(27)
Part no.
Specification sheet
Hirose electric co., ltd.
2
△
1/2
Code no.
CL680-3017-7-27
FORM HD0011-2-1