Applicable standard
Operating
temperature range
Storage
temperature range
Storage
-35C to +85C (Note 1)
-10C to +60C (Note 3)
Operating
humidity range
Voltage
20% to 80% (Note 2)
40% to 70% (Note 3)
humidity range
50V AC/DC
Voltage
Current
29V AC/DC
UL・
C-UL
rating
Current
1
AWG 26 to 28 : 1.5A/pin
AWG 26:1.5A/pin
AWG 28:1.5A/pin
AWG 30:1.0A/pin
AWG 32:0.8A/pin
AWG 34:0.5A/pin
DF57H-5P-1.2V(##)
Rating
-35C to +75C (Note 1)
Operating
temperature range
Applicable connector
Applicable contact
DF57-****SCF(A)(##)
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Insulation resistance
100V DC.
100 M MIN.
X
X
-
-
Voltage proof
500V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
30 times insertion and extraction.
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
No damage, crack or looseness of parts.
X
X
X
-
-
-
Vibration
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 10 cycles for 3 direction.
490 m/s2 duration of pulse 11 ms
at 3 times for 3 directions.
Shock
Environmental characteristics
Damp heat
Exposed at 40 ± 2 C , 90 to 95 %, 96 h.
(After leaving the room temperature for 1 to 2 h.)
① Insulation resistance: 100 M MIN.
② No damage, crack or looseness of parts.
① Insulation resistance: 100 M MIN.
② No damage, crack or looseness of parts.
X
X
-
-
(Steady state)
Rapid change of
temperature
Temperature -55 C → +85 C
Time
30 min → 30 min
Under 5 cycles.
(The transferring time of the tank is 2 to 3 min)
(After leaving the room temperature for 1 to 2 h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the packaged and unused product.
Count
Description of revisions
Designed
HK.HAYASHI
Checked
SZ.ONO
Date
1
△
1
DIS-H-00013960
20220616
20210823
20210823
20210823
Approved
Checked
Designed
Drawn
SJ.OKAMURA
SZ.ONO
HK.HAYASHI
TS.HONJO
20210820
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-344725-10-01
DF57AH-5S-1.2C(10)
Part no.
Specification sheet
Hirose electric co., ltd.
1
△
1/1
Code no.
CL0666-0110-0-10
FORM HD0011-2-1