COUNT
COUNT
DESCRIPTION OF REVISIONS
DATE
DESCRIPTION OF REVISIONS
CHKD
DATE
BY CHKD
BY
△
△
△
△
APPLICABLE STANDARD
Operating
Storage
-55℃ to 105℃ (Note1)
20% to 80% (Note2)
DF51K-6DS-2C(###)
250V AC/DC
-10℃ to +60℃ (Note3)
Temperature Range
Operating Humidity
Range
Temperature Range
Storage Humidity
Range
40% to 70% (Note3)
RATING
Applicable Connector
Voltage
AWG 30 : 0.5A
AWG 28 : 1A
Current
AWG 26 : 1.5A
AWG 22-24 : 2A
SPECIFICATIONS
TEST METHOD
ITEM
CONSTRUCTION
REQUIREMENTS
QT AT
General Examination
Visually and by measuring instrument.
Confirmed visually.
O
O
O
O
According to drawing.
Marking
ELECTRICAL CHARACTERISTICS
Contact Resistance
Millivolt Level Method
Insulation Resistance
20mV MAX, 1mA (DC or 1000Hz).
30 mΩ MAX.
O
O
O
-
-
-
500 V DC.
1,000 MΩ MIN.
Voltage Proof
650 V AC for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mechanical Operation
30 times insertion and extraction.
①Contact resistance: 30mΩ MAX
O
O
O
②No damage, crack or looseness of parts.
(Sn Plating)
-
-
-
Mechanical Operation
(Au Plating)
50 times insertion and extraction.
①Contact resistance: 30mΩ MAX
②No damage, crack or looseness of parts.
It takes out and inserts with a conformity connector. ①Insertion Force: 32.2N MAX
Mating and unmating
②Extraction Force: 1.7N MIN
force
(Sn Plating)
It takes out and inserts with a conformity connector. ①Insertion Force: 21.2N MAX
Mating and unmating
O
O
O
②Extraction Force: 1.5N MIN
force
(Au Plating)
-
-
-
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude 0.75 mm, ①No electrical discontinuity of 1μs.
at 10 cycles for 3 direction.
Acceleration 490 m/s2 duration of pulse 11 ms at 3
②No damage, crack or looseness of parts.
times for 3 directions.
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
Exposed at 40 ± 2 ℃ , humidity 90 to 95 %, 96 h.
①Contact resistance: 30 mΩ MAX.
②Insulation resistance: 500MΩ MIN.
③No damage, crack or looseness of parts.
O
-
(Steady State) (After leaving the room temperature for 1 to 2h.)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before pcb on board, after pcb board , operating temperature and
ꢀ
humidity range is applied for interim storage during transportation.
DRAWN
DESIGNED
CHECKED
APPROVED
RELEASED
J.S CHOI
18.03.02
J.S CHOI
18.03.02
S.M.LIM
18.03.02
T.S KANG
18.03.02
Unless otherwise specified, refer to IEC 60512.
NOTE QT: QUALIFICATION TEST AT: ASSURANCE TEST O: APPLICABLE TEST
PART NO.
HIROSE KOREA CO.,LTD.
SPECIFICATION SHEET
DF51KB-6DP-2DS(800)
CL 6652-0057-6-800
F-1-021(Rev.0)
CODE NO.(OLD)
DRAWING NO.
CODE NO.
1
2
ELC4-632588
CL