APPLICABLE STANDARD
OPERATING
STORAGE
TEMPERATURE RANGE
OPERATING
HUMIDITY RANGE
RATING
TEMPERATURE RANGE
STORAGE
HUMIDITY RANGE
APPLICABLE
-35 C TO +85 C(NOTE 1)
-10 C TO +60 C(NOTE 3)
40% TO + 80%(NOTE 2)
40% TO + 70%(NOTE 3)
VOLTAGE
DF1E(A)-*EP-2.5C
CONNECTOR
250 V AC/DC
APPLICABLE CABLE
CURRENT
AWG 22 TO 20: 3 A/pin
UL1007, 1061: AWG 22 TO 20
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION VISUALLY AND BY MEASURING INSTRUMENT.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
CONFIRMED VISUALLY.
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE 20 mV MAX. 1 mA (DC OR 1000 Hz).
MILLIVOLT LEVEL
30 m MAX.
X
-
METHOD
MECHANICAL CHARACTERISTICS
MECHANICAL
OPERATION
50 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 30 m MAX.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
X
X
X
-
-
-
VIBRATION
SHOCK
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 2 h, FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 1 s.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
490 m/s2 DURATION OF PULSE 11 ms
AT 3 TIMES FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 1 s.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
ENVIRONMENTAL CHARACTERISTICS
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -55→ 5 TO 35→+85→ 5 TO 35 C ① CONTACT RESISTANCE: 30 m MAX.
X
X
-
-
TIME
30→ 5 MAX → 30→ 5 MAX min
② NO DAMAGE, CRACK OR LOOSENESS
UNDER 5 CYCLES.
OF PARTS.
DAMP HEAT
(STEADY STATE)
EXPOSED AT 40 ± 2 C, 90 TO 95 , 96 h.
① CONTACT RESISTANCE: 30 m MAX.
② NO DAMAGE, CRACK OR LOOSENESS
OF PARTS.
REMARKS
NOTE1: INCLUDE THE TEMPERATURE RISING BY CURRENT.
NOTE2: NO CONDENSING.
NOTE3: APPLY TO UNUSED PRODUCT ON PACKAGED CONDITION.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
APPROVED
CHECKED
DESIGNED
DRAWN
SJ.OKAMURA
SZ.ONO
20210812
20210812
20210812
20210806
KT.NUMATA
NK.OOSHIMA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-162828-00-00
DF1E-2022PCFA
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL0541-1003-0-00
FORM HD0011-2-1