APPLICABLE STANDARD
OPERATING
STORAGE TEMPERATURE
RANGE
STORAGE
HUMIDITY RANGE
APPLICABLE
CONNECTOR
-35C TO +85C(NOTE1)
40% TO 80%(NOTE2)
100 V AC (DC)
-10C TO +60C(NOTE3)
40% TO 70%(NOTE3)
TEMPERATURE RANGE
OPERATING
HUMIDITY RANGE
RATING
VOLTAGE
DF19(G)-*S-1#(NOTE4)
AWG28: 1A/pin
AWG30:0.9A/pin
AWG32:0.8A/pin
CURRENT
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
X
X
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
AC 20mV, 1mA (DC OR 1000 Hz).
30 m MAX.
X
X
X
-
-
-
INSULATION RESISTANCE
100 V DC.
500 M MIN.
VOLTAGE PROOF
300 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
1) CONTACT RESISTANCE: 30 m MAX.
2) NO DAMAGE, CRACK OR LOOSENESS OF
PARTS.
X
-
VIBRATION
SHOCK
FREQUENCY 10 TO 55 Hz, SINGLE AMPLITUDE
0.75 mm, AT 10 CYCLES FOR 3 DIRECTIONS.
490 m/s2 DURATION OF PULSE 11 ms AT 3 TIMES FOR 3
1) NO ELECTRICAL DISCONTINUITY OF 1 s.
2) NO DAMAGE, CRACK OR LOOSENESS OF
PARTS.
X
X
-
-
DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
RAPID CHANGE OF
TEMPERATURE -55→5 TO 35→+85 →5 TO 35 C
TIME 30→2 TO 3 → 30 →2 TO 3 min
1) CONTACT RESISTANCE: 30 m MAX.
2) INSULATION RESISTANCE: 500 M MIN.
3) NO DAMAGE, CRACK OR LOOSENESS OF
PARTS.
X
TEMPERATURE
-
UNDER 5 CYCLES.
DAMP HEAT
EXPOSED AT 40±2 C, 90 TO 95 , 96 h.
X
X
(STEADY STATE)
-
-
RESISTANCE TO
SOLDERING HEAT
(1) REFLOW SOLDERING
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
≪REFLOW AREA≫
MAX 250C WITHIN 10 sec
MIN 230C WITHIN 60 sec
≪PREHEATING AREA≫
170 C TO 190 C 60sec TO 120 sec
PUT THROUGH IN REFLOW FUMACE TWICE.
LEAVE IN AMBIENT TEMPERATURE AND
HUMIDITY FOR 1 HOUR
(2) MANUAL SOLDERING
SOLDERING IRON TEMPERATURE 350±5 C,
FOR 5±1 sec. NO STRENGTH ON CONTACT.
SOLDERING TEMPERATURE: 245C
DURATION OF IMMERSION: SOLDERING, FOR 5 sec
SOLDERABILITY
REMARKS
A NEW UNIFORM COATING OF SOLDER SHALL
COVER MINIMUM OF 95 OF THE SURFACE
BEING IMMERSED.
X
-
NOTE1: INCLUDING THE TEMPERATURE RISE BY CURRENT.
NOTE2: NO CONDENSING
NOTE3: APPLY TO THE CONDITION OF LONGTERM STORAGE FOR UNUSED PRODUCTS BEFORE MOUNTED ON PCB. AFTER MOUNTED ON PCB,
OPERATING TEMPERATURE AND HUMIDITY RANGE IS APPLIED FOR INTERIM STORAGE DURING TRANSPORTATION.
NOTE4:#=TERMINATION STYLE MARKING.
(C:CRIMP SOCKET,F:FPC SOCKET,SD:SOCKET FOR FINE COAXIAL CABLES)
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
TS.KUMAZAWA
HK.HAYASHI
20200313
20200313
20200313
20200306
Unless otherwise specified, refer to IEC 60512.
DS.HIROWATARI
Note QT: Qualification Test AT: Assurance Test X:Applicable Test
DRAWING NO.
ELC-302815-52-00
DF19K-**P-1H(52)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL685-
FORM HD0011-2-1