Applicable standard
Operating
Storage
-35C to +85C(Notes 1)
-10C to +60C(Note3)
temperature range
temperature range
Storage
Operating
20 % to 80 % (Notes 2)
40 % to 70 %(Note3)
Rating
humidity range
humidity range
150 V AC (DC)
1
A/pin
Voltage
Current
Applicable
Applicable
DF13(G)-2630SCFA(##)
DF13-3032SCFA(##)
DF13-*DS-1.25C
Connector
Contact
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
AC 20mV, 1mA (DC OR 1000 Hz).
30 m MAX.
500 M MIN.
X
X
X
-
-
-
Insulation resistance
100 V DC.
Voltage proof
500 V AC for 1 min.
No flashover or breakdown.
Mechanical characteristics
Mechanical operation
50 times insertions and extractions.
1) Contact resistance: 30 m MAX.
X
X
X
-
-
-
2) No damage, crack or looseness of parts.
Vibration
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 2 h, for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times for 3
directions.
1) No electrical discontinuity of 1s.
2) No damage, crack or looseness of parts.
Shock
Environmental characteristics
Rapid change of
Temperature -55C→ +85C
1) Contact resistance:
30m MAX.
temperature
1
△
Time
Under 5 Cycles.
(The transferring time of the tank is 2 to 3 MIN)
30min→ 30min
2) Insulation resistance: 500 M MIN.
3) No damage, crack or looseness of parts.
X
-
Damp heat
Exposed at 40±2 C, 90 to 95 , 96 h.
X
-
(Steady state)
Resistance to soldering
heat
1) Reflow soldering
No deformation of case of excessive looseness
of the terminals.
X
≪Reflow area≫
-
250℃ MAX
230℃ MIN
10 sec MAX
60 sec MAX
≪Preheating area≫
170℃ to 190℃ 60 sec to 120 sec
Put through in reflow furnace twice,
leave in ambient temperature and humidity
for 1 hour.
2) Manual soldering
Soldering iron temperature :300℃,
Soldering time: 3sec.
No strength on contact.
Solderability
Soldered at solder temperature,
Solder shall cover a minimum of
X
-
245c for insertion duration, 3sec.
95 of the surface being immersed.
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB, operating temperature and humidity range is applied for interim storage during transportation.
Count
Description of revisions
DIS-H-00009653
Designed
HT.SATO
Checked
SZ.ONO
Date
1
△
1
20210608
20200313
20200313
20200313
20200306
Unless otherwise specified, refer to IEC 60512.
Approved
HS.OKAWA
Checked
Designed
Drawn
TS.KUMAZAWA
HK.HAYASHI
DS.HIROWATARI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-367982-52-00
Part no.
Code no.
DF13EA-*DP-1.25V(52)
Specification sheet
Hirose electric co., ltd.
1
△
1/1
CL536
FORM HD0011-2-1