Applicable standard
Operating
Storage
temperature range
Storage
humidity range
Current
Rating
temperature range
-35 C to +85 C(Notes 1)
-10C to +60 C(Note 3)
Operating
humidity range
1
20% to + 80%(Note 2)
150 V AC/DC
40% to + 70%(Note 3)
AWG 26 : 2.5A
AWG 28 : 2.0A
Voltage
1
Applicable cable
26 - 30 AWG
AWG 30 : 1.0A
Specifications
Test method
Item
Requirements
QT AT
Construction
General examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
X
X
X
Marking
Electric characteristics
Contact resistance
30 m MAX.
-
20 mV MAX, 1mA (DC or 1000Hz).
X
Millivolt level method
Mechanical characteristics
Contact insertion and
extraction force
Insertion force : 3.0N MAX.
Extraction force : 0.3N MIN.
□0.35±0.002mm by steel gauge.
-
-
-
-
×
Mechanical operation
50 times insertions and extractions.
① Contact resistance: 30 m MAX.
② No damage, crack or looseness of parts.
① No electrical discontinuity of 1 s.
② No damage, crack or looseness of parts.
① No electrical discontinuity of 1 s.
② No damage, crack or looseness of parts.
X
Vibration
Shock
Frequency 10 to 55 Hz, single amplitude
0.75 mm, at 2 h, for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times for 3
directions.
X
X
Environmental characteristics
Rapid change of
temperature
Temperature –55→15 to 35 →+85→15 to35 c
Time 30→10 to 15→ 30 →10 to 15min
① Contact resistance: 30 m MAX.
② No damage, crack or looseness of parts.
-
-
X
X
1
Under 5 cycles.
Damp heat
Exposed at 40 ± 2 c, 90 to 95 , 96 h.
① Contact resistance: 30 m MAX.
② No damage, crack or looseness of parts.
(Steady state)
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing.
Note 3: Apply to the condition of long term storage for unused products before mounted on PCB.
After mounted on PCB, operation temperature and humidity range is applied for interim storage during transportation.
1
Count
Description of revisions
Designed
Checked
Date
1
△
4
HT.SATO
SZ.ONO
20190531
20050105
20050105
20050105
20050105
Unless otherwise specified , refer to IEC 60512.
Approved
Checked
Designed
Drawn
KJ.KATAYOSE
TY.OMA
TS.KUMAZAWA
TS.KUMAZAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing no.
ELC-071220-05-03
DF13-2630SCFA(05)
Part no.
Specification sheet
1
△
1/1
Hirose electric co., ltd.
Code no.
CL536-0298-5-05
FORM HD0011-2-1