Applicable standard
Operating Temperature Range
-35 to +85C (Note1)
20% to 80% (Note2)
AC 150V (DC)
Storage Temperature Range
Storage Humidity Range
Applicable Connector
-10 C to +60C (Note3)
40% to 70% (Note3)
DF13-*S-1.25C
Rating
Operating Humidity Range
Voltage
DF13-2630SCF
Current
1A/pin
Applicable crimp contact
DF13G-2630SCF
DF13-3032SCF
Specifications
Test method
Item
Requirements
QT AT
Construction
General Examination
Marking
X
X
X
X
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
Electric Characteristics
Contact Resistance
X
30 m MAX.
100m A (DC or 1000 Hz).
-
X
X
-
-
Insulation Resistance
Voltage Proof
100 V DC.
500 M MIN.
500 V AC for 1 min.
No flashover or breakdown.
Mechanical Characteristics
Mechanical Operation
30 times insertion and extraction.
1.Contact resistance: 30 m MAX.
2.No damage, crack or looseness of parts.
X
X
-
-
Vibration
Frequency 10 to 55 Hz, single amplitude 0.75 mm,
at 2 h, for 3 directions.
1.No electrical discontinuity of 1μs.
2.No damage, crack or looseness of parts.
Acceleration 490 m/s2 duration of pulse 11 ms at 3
X
-
Shock
times for 3 directions.
Environmental Characteristics
Damp Heat
1.Contact resistance: 30 m MAX.
2.Insulation resistance: 500 M MIN.
3.No damage, crack or looseness of parts.
1.Contact resistance: 30 m MAX.
2.Insulation resistance: 500 M MIN.
3.No damage, crack or looseness of parts.
X
X
X
Exposed at 40 ± 2C , humidity 90 to 95 %, 96 h.
-
-
-
(Steady State)
(After leaving the room temperature for 1 to 2h.)
Rapid Change Of
Temperature
Temperature -55→ 5 to 35→85→ 5 to 35 C
Time
Under 5 cycles.
Resistance to soldering heat 1) Solder bath method
Soldered at solder temperature,
30→ 10 to 15 →30→ 10 to 15 min
1.Contact resistance: 40 m MAX.
2.Insulation resistance: 100 M MIN.
3.No damage, crack or looseness of parts.
250 C,for in immersion, duration, 10 sec.
2) Manual soldering
Soldering iron temperature: 300 C,
Soldering time: 3 sec.
No strength on contact.
Solderability
Soldering temperature : 240C
Duration of immersion :soldering, for 3 sec.
1.Contact resistance: 40 m MAX.
2.Insulation resistance: 100 M MIN.
3.No damage, crack or looseness of parts.
X
-
Remarks
Note 1: Include the temperature rising by current.
Note 2: No condensing
Note 3: Apply to packed condition.
CHECKED
DATE
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
0
△
20211216
20211216
20211215
20211215
APPROVED
CHECKED
DESIGNED
DRAWN
SJ.OKAMURA
SZ.ONO
TH.SATO
TH.SATO
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
SPECIFICATION SHEET
ELC-162420-25-00
DRAWING NO.
DF13-*P-1.25DS(25)
PART NO.
CODE NO.
1/1
HIROSE ELECTRIC CO., LTD.
0
△