Panel Mount
Datasheet
Power Plus DC Series
• Ratings from 10A to 100A @ 60 VDC
• LED Status Indicator
• Mosfet Output
• DC control
• Relays are easily paralleled for higher-current
applications
• UL Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• EMC Compliant to Level 3
• Epoxy Free Design
• Optional IP20 Cover
• PWM to 1K Hz
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
4-32 VDC
10A
DC60D10
20A
DC60D20
40A
DC60D40
60A
DC60D60
80A
DC60D80
100A
DC60D100
AVAILABLE OPTIONS
Termination
Blank: Screws & clamps
K: Installed standoffs with (1)
screws for PC Board
mounting (IP00 only)
Control Voltage
D: 4-32 VDC
Thermal Pad
Blank: Not Included
H: Included
Series
K
DC
60
D
40
C
H
Operating Voltage
Cover
Rated Load Current
60: 1-60 VDC
Blank: Not Included (IP00)
C: Included (IP20)
10: 10 Amps
20: 20 Amps
40: 40 Amps
60: 60 Amps
80: 80 Amps
100: 100 Amps
Required for valid part number
For options only and not required for valid part number
Not all part number combinations are available.
Contact Crydom Technical Support for information on
the availability of a specific part number.
*
OUTPUT SPECIFICATIONS (2)
Description
Recommended Operating Voltage [Vdc]
Absolute Maximing Rating [Vdc]
10A
1-48
60
20A
1-48
60
40A
1-48
60
60A
1-48
60
80A
1-48
60
100A
1-48
60
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum Load Current [Adc] (1)(3)
Minimum Load Current [mA] (4)
Maximum Surge Current (10msec) [Adc]
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Maximum On-State Resistance [RDS-ON] [mΩ]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Minimum Heat Sink for Rated Current @ 40°C [°C/W]
Maximum Pulse Width Modulation Frequency [Hz] (5)
0.1
10
2.5
78
0.17
17
1.6
5
0.1
20
2.5
108
0.30
15
1.6
5
0.1
40
2.5
163
0.36
9
0.74
2
900
0.1
60
2.5
200
0.51
8.5
0.74
1
0.1
80
2.5
258
0.46
5.8
0.51
0.5
0.1
100
2.5
326
0.56
5.6
0.51
0.5
700
1000
1000
900
700
(2)
INPUT SPECIFICATIONS
Description
DC Control
4-32 VDC
-32 VDC
4 VDC
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage (6)
Must Turn-Off Voltage
1 VDC
Minimum Input Current (for on-state)
Maximum Input Current
11 mA
14 mA
Nominal Input Impedance
Maximum Turn-On Time [µsec]
Maximum Turn-Off Time [µsec]
Current Regulated
75
150
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.