Panel Mount
Datasheet
Series 1 240 VAC
• Ratings from 10A to 125A @ 24-280 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-280 VAC
18-36 VAC
10A
D2410
A2410
A2410E
25A
D2425
A2425
A2425E
50A
D2450
A2450
A2450E
75A
D2475
A2475
A2475E
90A
D2490
A2490
A2490E
110A
D24110
A24110
A24110E
125A
D24125
A24125
A24125E
AVAILABLE OPTIONS
Control Voltage
A: 90-280 VAC
D: 4-32 VDC
Switching Type
Blank: Zero Voltage Turn-On
(4)
-10: Instantaneous Turn-On
Overvoltage Protection Snubber
Blank: Not Included
Blank: Not Included
S: Included
(3)
AxxxxE: 18-36 VAC
P: Included
A
E
K
P
G
S
H
-10
24
10
Operating
Voltage
Rated Load Current
Termination
Input Status LED
Blank: Not Included
G: Included
Thermal Pad
10: 10 Amps
Blank: Screw
F: Quick Connect (1)
(Up to 50 Amps only)
Blank: Not Included
H: Included
24: 24-280 VAC 25: 25 Amps
50: 50 Amps
75: 75 Amps
(2)
K: Hex standoffs
90: 90 Amps
110: 110 Amps
125: 125 Amps
Required for valid part number
For options only and not required for valid part number
* Not all part number combinations are available.
Contact Crydom Technical support for information on
the availability of a specific part number.
OUTPUT SPECIFICATIONS (5)
Description
10A
25A
50A
75A
90A
110A
125A
Operating Voltage (47-440Hz) [Vrms] (6)
Transient Overvoltage [Vpk] (3)
24-280
600
24-280
600
24-280
600
24-280
600
24-280
600
24-280
600
24-280
600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (7)
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Load Current [Arms] (2)(8)
1
500
10
1
500
25
1
500
50
1
500
75
1
500
90
1
500
110
1
500
125
Minimum Load Current [mArms]
150
150
150
150
150
250
250
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vrms]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (at Maximum load) (3)
115/120
1.15
1.03
66/60
0.5
239/250
1.15
0.8
285/259
0.5
597/625
1.30
0.45
1770/1621
0.5
954/1000
1.15
0.3
4555/4150
0.5
1145/1200
1.15
0.27
6560/5976
0.5
1432/1500
1.15
0.25
10249/9338
0.5
1670/1750
1.15
0.22
13950/12709
0.5
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com
Copyright © 2018 Crydom Inc. Specifications subject to change without notice.