TOTAL POWER INT.
D60 AC-DC 60W POWER SUPPLY WITH DUAL OUTPUT
.LOW COST, HIGH RELIABILITY
.105ºC OUTPUT CAPACITOR
.INTERNATIONAL AC INPUT RANGE
.COMPACT SIZE, LIGHT WEIGHT
.100% FULL LOAD BURN-IN TEST
.BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
D-60A
D-60B
MODEL
SPECIFICATION
CH1
5V
CH2
12V
CH1
5V
CH2
24V
DC OUTPUT VOLTAGE
OUTPUT V. TOLERANCE
OUTPUT RATED CURRENT
OUTPUT CURRENT RANGE
RIPPLE & NOISE
±2%
±6%
±2%
±5%
4A
3A
3A
1.8A
0.3-6A
75mVp-p
±0.5%
±0.5%
0.2-4A
150mVp-p
±1%
0.3-6A
75mVp-p
±0.5%
±0.5%
0.2-2.2A
150mVp-p
±0.5%
±4%
LINE REGULATION
LOAD REGULATION
DC OUTPUT POWER
EFFICIENCY
±4%
56W
73%
58W
76%
DC VOLTAGE ADJ.
CH1:+10,-5%
CH1:+10,-5%
INPUT VOLTAGE RANGE
AC CURRENT
85~264VAC 47~63Hz; 120~370VDC
2A/115V 1A/230V
INRUSH CURRENT
LEAKAGE CURRENT
OVERLOAD PROTECTION
COLD START 30A/115V 60A/230V
<1mA/240VAC
105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY
CH1:5.75~6.75V
OVER VOLTAGE PROTECTION
OVER TEMP. PROTECTION
TEMP. COEFFICIENT
SETUP, RISE, HOLD UP TIME
VIBRATION
----------
±0.03% / ºC (0~50ºC) ON +5V OUTPUT
800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
-10ºC~+60ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH
-20ºC~+85ºC, 10%~95% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY
DIMENSION
159*97*38mm CASE:901
WEIGHT
0.55Kgs
SAFETY STANDARDS
EMC STANDARDS
UL1012, TUV EN60950, IEC950, UL1950 APPROVED
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION
NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER.
7.C2,3,6 MUST BE REMOVED.
2000-10-03