CXA20 Series
S i n g l e a n d d u a l o u t p u t
• 4:1 input voltage range
• No minimum load on singles
• 6 A on 3.3 V output (@ 48 Vin) at 50 ˚C in still air
• Wide operating temperature with overtemperature
protection
• 10ꢀ output voltage trim
• Remote On/Off control
• Overvoltage protection
• Available RoHS complaint
The CXA20 is a new 20 W addition to the CXA family of open-frame, isolated, dc-dc
converters. The five model series features a 4:1 input voltage range of 18 Vdc to
75 Vdc, making it suitable for a wide variety of communications and distributed
power applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20
provides an easy upgrade option for new and existing Artesyn customers seeking a
high-performance, cost-effective power supply. The CXA20 is available in output
voltages of 3.3 V, 5 V, 12 V, 5 V and 12 V. The 3.3 V version delivering up to 6 A is
fully rated to 20 W. Typical efficiency for the CXA20 is 83%. The CXA20 offers remote
ON/OFF as well as overvoltage, overtemperature and short circuit protection
features.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Voltage accuracy
1.0%
EN55022, ext. cap. (Note 5)
Level A
Level B
EN55022, external filter,
VDE0878, 48V models
Line regulation
(LL to HL)
Singles/dual positives
0.1%
0.1%
Dual negatives
Radiated emissions
Immunity:
EN55022-B
See App. Note 107
Load regulation
(not incl. cross reg.)
Full load to minimum load
S3V3
Singles/dual positives
Dual negatives
0.2%
0.1%
0.1%
ESD air
EN61000-4-2 8 kV (NP), 15 kV (RP)
EN61000-4-2 6 kV (NP), 8 kV (RP)
EN61000-4-4 2 kV (NP), 4 kV (LFS)
EN61000-4-4 1 kV (NP), 2 kV (LFS)
ESD contact
EFT DC power
EFT signal
Minimum load
Singles
Duals (for imbalanced loads)
None
10%
Radiated field enclosure EN61000-4-3 10 V/m (NP)
Surges indoor signal
Conducted (dc power)
Conducted (signal)
Input transients
EN61000-4-5 500 V (RP)
EN61000-4-6 10 V (NP)
EN61000-4-6 10 V (NP)
ETS 300 132-2, ETR 283
Ripple and noise
20 MHz bandwidth
S3V3, S05, D05
S12, D12
All models
75 mV pk-pk max.
100 mV pk-pk max.
20 mV rms max.
GENERAL SPECIFICATIONS
Temperature coefficient
Overvoltage protection
0.02%/°C
Efficiency
See table
120 ˚C
See Application Note 107
Overtemp. shutdown
Short circuit protection
Short <20 mΩ
Hiccup
Continuous
automatic recovery
Isolation voltage
Input/output test voltage
Fixed
1500 Vdc
400 kHz
Switching frequency
Transient response
25% load step
2.0% max. dev.,
300 µs recovery to
Approvals and standards
(See Notes 6,7,8)
EN60950
UL1950 File No. E136005
within total error band
Material flammability
Weight
UL94V-0
Load cross regulation
(See Note 1)
10% load to full load,
either output
7.0%
26 g (0.92 oz)
MTBF
(Representative model
48S05J @ 48 Vin)
MIL-HDBK-217F
Parts stress method
Ground Benign @ 25 °C
3,485,000 hours
INPUT SPECIFICATIONS
Input voltage range
Input fuse
48 Vin nominal
18-75 Vdc
2.0 A
ENVIRONMENTAL SPECIFICATIONS
HRC recommended
48 V ETS300-132
Thermal performance
Operating ambient
-40 °C to +60 °C,
(See Note 9)
-55 °C to +125 °C
temperature
Max. input rise
and fall time
5 V/ms
Non-operating
ETS 300 019-2-3
Air temperature
Classes T3.1, 3.2, 3.3, 3.5
UVLO turn ON voltage
UVLO turn OFF voltage (See Note 4)
(See Note 4)
92%
86%
Low: IEC 68-2-1
High: IEC 68-2-2
-40 °C
+60 °C
Change: IEC 68-2-14 -40 °C to +60 °C
Remote ON/OFF
Logic compatibility
CMOS/TTL/Open Collector
Open circuit or >2 Vdc
<1.2 Vdc
Relative humidity
IEC 68-2-56
IEC 68-2-30
10% to 100% RH
Condensation
ON
OFF
File Name: cxa20.pdf Rev (02): 09 Dec 2005