DC-AC INVERTER UNIT
CXA-0326 (5W DUAL OUTPUTS WITH DIMMING FUNCTION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps, low power LCD
back-light. Application includes industrial PC and LCD monitor.
Applicable LCD; NL6448BC26-01 (NEC 8.4 inch double lamp type)
Lamp Voltage 410Vrms
Lamp Current 5mArms
Lamp Start Up Voltage 1200Vrms
FEATURES :
Wide operating temperature range
Alarm signal function
PWM dimming type.
Silicon Coating in High Voltage area
TEMPERATURE & HUMDITY :
Operating Temperature Range -10 °C
Storage Temperature Range
Humidity
~
~
+70 °C
+85
-30
°C
°C
95 %RH max
103 ± 0.5
97.0 ± 0.2
DIMENSIONS :
(3.0)
CN2
2 - Ø2.9 ± 0.2
Unit : mm
Weight :25 (g) typ.
Note 1 : Please keep minimum of 2mm clearance (all directions) between inverter
high voltage area as marked on mechanical drawing and any conductors.
No.
1
Part Description
PWB
Qty.
1
Note
UL94V-0
t=1.0mm
(Molex)
(JST)
2
Connector CN1
Connector CN2 , CN3
1
53261-0890
3
2
SM02(8.0)B-BHS-1
CN1 : 53261-0890 (Molex)
CN2 : SM02(8.0)B-BHS-1 (JST)
Pin
Symbol
Vhigh1
N.C.
Note
Pin
Symbol
Note
410 Vrms (5mArms)
CN2-1
CN2-2
CN2-3
CN1-1
CN1-2
CN1-3
CN1-4
Vin
9 ~ 19V
-
Vlow1
0V
GND
Vrmt
0 V
CN3 : SM02(8.0)B-BHS-1 (JST)
0 ~ 0.4V : OFF
2.5V ~ Vin : ON
Pin
Symbol
Vhigh2
N.C.
Note
CN1-5
410 Vrms (5mArms)
CN3-1
CN3-2
CN3-3
CN1-6
CN1-7
CN1-8
Vbr
0 ~ 2.5V
0V
-
GND
Vlow 2
0V
*1
Vst
0V / 5V
*1. This is an output pin and it is active high (+5V)
if any Lamp opens / fails
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 80
Email:
All specification are subject to change without notice.
Page ( 1 / 2 )
VER1-1, 23 June 2005