COUNT
COUNT
REV
DESCRIPTION OF REVISIONS
BY
JSK
JSK
CHKD DATE
REV
DESCRIPTION OF REVISIONS
RE-2-1426(M.P. Release)
Revised
BY
JSK
KYG
CHKD DATE
-
-
Revised
Revised
LHJ
LHJ
19.10.07
20.01.16
-
-
LHJ
LHJ
20.02.11
21.08.31
1
2
3
4
Universal Serial Bus Type-C Cable and Connector Specification Release 2.1
APPLICABLE STANDARD
Universal Serial Bus Type-C Connectors and Cable Assemblies Compliance Document Revision 2.1b
1.25A max. for each power pin (i.e. A1, A4, A9, A12, B1, B4, B5, B9, B12)
0.25A for the other pins
CURRENT
VOLTAGE
RATING
20V AC/DC
OPERATING CONDITION
STORAGE CONDITION
-20℃ ~ +80℃ (INCLUDING TEMP. RISE), 95% RH max. (NON-CONDENSING)
-30℃ ~ +80℃ (WITH PACKING), 15% ~ 70% RH
Para.
1
Test Description
Test Procedure
Test Requirement
QTAT
O O
Examination of product Visual inspection.
No physical damage.
Electrical Requirements
Testing voltage : 20V DC
Testing current : 3A
250mV for GND and
500mV for VBUS
2
Voltage Drop
O -
Mechanical Requirements
EIA 364-38B
Fix the head part of the cable
Apply 40N min of steady state axial load to
the cable at 500mm from the edge of the
plug for one minute.
No discontinuities greater than 1μs
No physical damage.
3
Cable Pull Out
O -
EIA 364-41
Mated condition.
Speed : 13 cycle/min
Cycle : 100 cycles
Angle : Total 120˚ (left & right each 60˚)
Load : 1lbf (4.45N)
No discontinuities greater than 1μs
No physical damage.
4
Cable Flex
O -
Perpendicular moments are applied to
the plug with a 5mm ball tipped probe.
No discontinuities greater than
5
4 Axis Continuity
20N force at 15mm from receptacle shell for 1μs duration in any of the four
10 seconds in four directions of up or down orientations tested.
and left or right.
O -
REMARKS
DRAFT
DESIGN
CHECK
APPROVAL
RELEASE
ENG
21.08.31
DEPT
J.H.BOO
19.03.25
J.H.BOO
19.03.25
H.J.LEE
H.J.LEE
19.03.25
19.03.25
NOTE) QT : QUALIFICATION TEST, AT : ASSURANCE TEST, O: Applicable Test
DWG NO CL NO
PART NO
CX60-24S-1000-CS
ELC4-632946-00
CL 6240-0030-7-000
1
HIROSE KOREA.CO.,LTD
PRODUCT SPECIFICATION
2