MODEL CUB®5 - MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR

CUB5RLY0 数据手册

 浏览型号CUB5RLY0的Datasheet PDF文件第2页浏览型号CUB5RLY0的Datasheet PDF文件第3页浏览型号CUB5RLY0的Datasheet PDF文件第4页浏览型号CUB5RLY0的Datasheet PDF文件第5页浏览型号CUB5RLY0的Datasheet PDF文件第6页浏览型号CUB5RLY0的Datasheet PDF文件第7页 
Bulletin No. CUB5-L  
Drawing No. LP0584  
Released 04/16  
Tel +1 (717) 767-6511  
Fax +1 (717) 764-0839  
www.redlion.net  
MODEL CUB®5 - MINIATURE ELECTRONIC 8-DIGIT DUAL  
COUNTER AND RATE INDICATOR  
LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING  
0.46" (11.7 mm) HIGH DIGITS  
OPTIONAL SETPOINT OUTPUT CARD  
OPTIONAL SERIAL COMMUNICATIONS CARD (RS232 or RS485)  
OPTIONAL USB PROGRAMMING CARD  
OPERATES FROM 9 TO 28 VDC POWER SOURCE  
PROGRAMMABLE SCALING FOR COUNT AND RATE  
BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL  
QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION)  
BUILT-IN BATCH COUNTING CAPABILITY  
U
R
C L US LISTED  
IND. CONT. EQ.  
51EB  
DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT  
NEMA 4X/IP65 SEALED FRONT BEZEL  
COUNTER  
GENERAL DESCRIPTION  
The CUB®5 provides the user the ultimate in flexibility, from its complete  
user programming to the optional setpoint control and communication capability.  
The meter can be programmed as a single or dual counter with rate indication  
capability. The display can be toggled either manually or automatically between  
the selected displays.  
The CUB5 receives incoming pulses and multiplies them by the Count Scale  
Factor to obtain the desired reading for the count display. Input A accepts the  
signal for the count and Input B is used for quadrature, dual counter, anti-  
coincidence counting, or up/down control counting.  
RATE  
The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in  
two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight  
version is user selectable for green or red backlighting with variable display  
intensity.  
The counter is programmable for one of eight different count modes,  
including bi-directional and quadrature. When programmed as a dual counter,  
each counter has a separate scale factor and decimal points. In the counter/rate  
indicator mode, each have their own scaling and decimal point read-outs in  
different engineering units. The internal batch counter can be used to count  
setpoint output activations.  
The rate indicator utilizes the signal at Input A to calculate the rate value  
using a time interval method (1/tau). The unit counts on the negative edge of the  
input pulses. After the programmed minimum update time elapses and the next  
negative edge occurs, the unit calculates the input rate based on the number of  
edges that occurred during the elapsed time. The input rate is then multiplied by  
the rate scaling value to calculate the rate display.  
At slower rates, averaging can be accomplished by programming the rate  
minimum update time for the desired response. Extensive scaling capabilities  
allow practically any desired reading at very slow count rates.  
The meter has two separate inputs which provide different functions  
depending on which operating mode is selected. Input A accepts the signal for  
the Count and/or Rate displays, while Input B accepts the signal for the Count  
display or direction control. In the anti-coincidence mode, both inputs are  
monitored simultaneously so that no counts are lost. The resulting display can  
be chosen as the sum or difference of the two inputs. The Rate Indicator has  
programmable low (minimum) and high (maximum) update times to provide  
optimal display response at any input frequency. There is a programmable user  
input that can be programmed to perform a variety of functions.  
The capability of the CUB5 can be easily expanded with the addition of  
option cards. Setpoint capability is field installable with the addition of the  
single setpoint relay output card or the dual setpoint solid state output card.  
Serial communications capability for RS232 or RS485 is added with a serial  
option card.  
SAFETY SUMMARY  
All safety related regulations, local codes and instructions that appear in this  
literature or on equipment must be observed to ensure personal safety and to  
prevent damage to either the instrument or equipment connected to it. If  
equipment is used in a manner not specified by the manufacturer, the protection  
provided by the equipment may be impaired.  
Do not use this meter to directly command motors, valves, or other actuators  
not equipped with safeguards. To do so can be potentially harmful to persons or  
equipment in the event of a fault to the meter.  
The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor  
Power Supply (MLPS), which attaches directly to the back of a CUB5. The  
MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the  
unit and sensors.  
CAUTION: Risk of Danger.  
Read complete instructions prior to  
installationand operation of the unit.  
CAUTION: Risk of electric shock.  
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.  
DIMENSIONS In inches (mm)  
.13 (3.3)  
ON ECE  
+.024  
1.30  
1
2
3
4
-.000  
+6  
1.29 (32.8)  
1.54 (39.1)  
(33  
)
9876543.2  
-0  
SEL  
RST  
+.025  
-.000  
+8  
2.95 (74.9)  
1.71  
(43.4)  
2.68  
(68  
.15 (3.8)  
)
-0  
1

与CUB5RLY0相关器件

型号 品牌 获取价格 描述 数据表
CUBC001S-B01 FOXCONN

获取价格

Interconnection Device
CUBC001S-B05 FOXCONN

获取价格

Interconnection Device
CUBD001B-X21-DF FOXCONN

获取价格

Interconnection Device, LEAD FREE
CUBD003B-P01 FOXCONN

获取价格

Interconnection Device
CUBD003B-P01-EF FOXCONN

获取价格

Interconnection Device, ROHS COMPLIANT
CUBD003D-P01-EF FOXCONN

获取价格

Interconnection Device, LEAD FREE
CUBD003S-028 FOXCONN

获取价格

Interconnection Device,
CUBD005C-001 FOXCONN

获取价格

Interconnection Device,
CUBD005C-K11A-DF FOXCONN

获取价格

Interconnection Device, LEAD FREE
CUBD005C-K11-DF FOXCONN

获取价格

Interconnection Device, LEAD FREE