CS-625 Series Current Switch

CS625 数据手册

 浏览型号CS625的Datasheet PDF文件第2页 
CS-625 Series Current Switch  
Installation Instructions  
Introduction  
The CS-625 current switch is a solid-state switch that monitors  
line current for electrical loads such as pumps, conveyors,  
machine tools or fans and closes the output contacts when  
the adjustable trip point is exceeded. It is typically used to  
monitor motor operation and can be used to determine  
on/oꢀ status, proof of operation, motor failure or belt loss.  
The sensor requires no external power as it is totally powered  
by induction from the primary AC line being monitored. The  
trip setpoint is adjustable in three jumper-selectable ranges  
from a minimum value (1 Amp) up to 175 Amps by rotating  
the adjustment pot counter-clockwise.  
The output contacts can switch loads up to 1 Amp 240 Vac.  
**** WARNING ****  
- Electric Shock Hazard, Use Caution  
- Disconnect and lock out power before installation  
- Follow national and local electrical codes  
Installation  
-Ensure the selected device has the correct ratings for  
application  
-Set the range jumper to the desired range. (See Figure 1)  
-Mount the sensor with two screws through the base .  
- Read and understand these instructions before installing  
- Installation only by qualiꢁed electrical personnel  
- Do not rely on this device to indicate line power  
- Only install this device on insulated conductors  
- Only install on 600 Vac maximum conductors  
- Do not use this device for life-safety applications  
- Do not install in hazardous or classiꢁed locations  
- Install this product in a suitable electrical enclosure  
- Failure to follow these instructions may result in  
serious injury or death.  
-Read all warnings before beginning  
The base has an integral mounting tab to allow screw  
mount to a surface.  
If predrilling is required, the actual device may be used to mark holes. The  
mounting holes in the base will accommodate up to a #10 size screw (Not  
supplied) . See Figure 2  
Figure 3  
Place the monitored conductor through the sensor hole and reconnect. See  
Figure 3.  
-The CS-625 is not polarity sensitive. Use shielded wiring for all connections and  
do not locate the device wires in the same conduit with wiring used to supply  
inductive loads such as motors. Make all connections in accordance with national  
and local codes.  
-Reconnect the power  
Figure 1  
Range Jumper Selector  
(Factory set on High)  
Jumper Position Legend  
RANGE  
HIGH  
MID  
Amps  
Jumper  
NONE  
MID  
Setpoint  
CCW To  
Increase  
1-6  
6-40  
40-175  
HIGH  
For Low Range  
Remove Jumper  
CS-625  
Current Switch  
Low  
Switch Rating  
240 Vac 1 Amp  
40C Max  
Mid  
CS-625 Ranges  
600 Vac max  
Insulated Conductors  
Only  
Low (L) = 1 to 6 Amps  
Mid (M) = 6 to 40 Amps  
High (H) = 40 to 175 Amps  
High  
Figure 4  
Figure 2  
Wiring for using an external power supply  
RANGE  
HIGH  
MID  
Amps  
Jumper  
NONE  
MID  
Setpoint  
CCW To  
Increase  
1-6  
Power  
Input  
6-40  
40-175  
HIGH  
CS-625  
Common  
Relay  
Current Switch  
Switch Rating  
240 Vac 1 Amp  
40C Max  
Common  
+Power  
Greystone Energy Systems, Inc. 150 English Drive, Moncton, NB E1E 4G7 Canada Tel: +1-506-853-3057 Tollfree (North America): +1-800-561-5611 Fax: +1-506-853-6014  
Email: support@greystoneenergy.com Web: www.greystoneenergy.com  

与CS625相关器件

型号 品牌 获取价格 描述 数据表
CS625N3A JSMC

获取价格

TO-220MF-K1
CS6-28 SUPERWORLD

获取价格

POWER TRANSFORMER
CS62LS4008FC ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS62LS4008FI ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS62LS4008GC ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS62LS4008GI ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS62LS4008HC ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS62LS4008HI ETC

获取价格

Low Power CMOS SRAM 512K X 8 Bits
CS63 VISHAY

获取价格

Customer Special Edgewound Resistor (CS63), Wirewound Resistors, Industrial Power, Tubular
CS630 IXYS

获取价格

Phase Control Thyristor