Type
Vi
Vo
Io
195 to 253 Vac out1: 3.3 V 100 mA
and
28 to 115 Vdc
COMBI/E1
-3.3
out 2: 40V 120 mA
FEATURES
Uko INTERFACE (DC) and MAINS (AC) inputs
to enable NPM (Normal Power Mode) and
RPM (Restricted Power Mode) CONDITIONS
INPUT FILTER TO MEET EMI requirements
PEAK INPUT OVERVOLTAGE WITHSTAND-
ING
ORDERING NUMBER: GS-COMBI/E1-3.3
AC INPUT PROTECTION FUSE
INPUTS TO OUTPUTS INSULATION
U-INTERFACE ACCORDING TO ETR080
2 INSULATED OUTPUTS:
Vo1=3.3 V for NT1 logics
Vo2=40 V for "S" interface
S-INTERFACE ACCORDING TO ETS 300
012
MTBF: 300 Kh, according to MIL HDBK 217-F
Operating Temperature: -10 to +70oC
AUXILIARY LOGIC OUTPUT TTL-COMPAT-
IBLE for LED & NPM/RPM MODE indication.
INTERNAL RELAY FUNCTION FOR Vo2 PO-
LARITY REVERSE
"S"
INTERFACE
OUTPUT
CHARAC-
TERISTICS:
- Peak output of 220 mA for 150 ms
- Typical output power 4,5 W
- Output filtering to meet ETSI requirements
- Hold up time: 20 ms with 4,5 W output power
- Continuous short circuit protection
- Peak overvoltage withstand:1KV for 10/700 us
transversal
May 2001