CN-A24 Series
50 & 100W 14.4 to 36VDC Input DC-DC Converters
Features
14.4 - 36VDC Input
IEC 61373 Shock and Vibration
Base-plate Cooled
Full Power at 100°C base plate
Small Size
Quarter Brick Footprint
Wide input range
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
Input Voltage Range
Input Current
VDC
VDC
A
5V
12V
24V
14.4 - 36VDC (40V transient for 3 seconds)
2.48 - 4.91A (model dependant)
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection
Remote Sense
VDC
mV
mV
mV
%
4.5 - 6
100
20
10.8 - 13.2
21.6 - 26.4
240
150
48
96
105 - 140%
96
192
40
%
-
125 - 145% (Cycle input or remote on/off to reset)
Yes
Remote On/Off
-
°C
°C
%/°C
%RH
-
Yes; Low = ON, Open = OFF
-40°C to +100°C Baseplate
-40°C to +100°C
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity (non condensing)
Cooling
0.02%/°C
5 - 95% RH Operating and Non Operating
Conduction (See Installation Manual for heatsink selection)
Withstand Voltage
VAC Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min
Isolation Resistance
-
-
>100M at 25C and 70%RH, Output to Base plate 500VDC
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
IEC61373 - Category 1, Grade B
Vibration
Shock
Safety Agency Certifications
Weight (Typ)
(1)
(1)
-
-
g
196.1m/s2, IEC61373 - Category 1, Grade B
UL60950-1, CSA60950-1, EN60950-1
70g
Size (WxHxD)
Warranty
in(mm)
yrs
1.45 x 0.5 x 2.28” (36.8 x 12.7 x 57.9)
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Compliant to EN50155 & IEC60571
1-800-526-2324 • www.us.tdk-lambda.com/lp/
192