Features
■ RoHS compliant*
Applications
■ HDMI 1.4
■ ESD protection >25 kV
■ Low capacitance <0.5 pF
■ Low leakage current <50 nA
■ Digital Visual Interface (DVI)
■ USB 3.0 / USB OTG
■ Memory protection
■ SIM card ports
ChipGuard® MLC Series - ESD Protectors
Device Symbol
General Information
The ChipGuard® MLC Series has been specifically designed to protect sensitive
electronic components from electrostatic discharge damage. The MLC family has been
designed to protect equipment to IEC61000-4-2, Level 4 (±8 kV Contact / ±15 kV Air
Discharge) ESD specifications targeted for high speed USB 3.0/USB OTG, HDMI 1.4,
DVI or IEEE1394 applications.
V
The ChipGuard® MLC Series has been manufactured to provide low 0.5 pF capacitance
and leakage currents less than 5 nA with excellent clamp qualities, making the family
almost transparent under normal working conditions.
Electrical Characteristics @ 25 °C (unless otherwise noted)
CG0402MLC-
Parameter
Symbol
Unit
3.3LG
05LG
12LG
24LG
3.3LGA 05LGA
3.3
12LGA
12
24LGA
Typical Continuous Operating Voltage
Typical Clamping Voltage (Note 1)
Maximum Capacitance @ 1 VRMS 1 MHz
Maximum Leakage Current @ Max. VDC
Typical Trigger Voltage (Note 2)
V
3.3
5
12
24
5
24
V
V
DC
V
25
0.5
5
C
O
L
C
pF
nA
V
I
V
R
250
1
T
T
Maximum Response Time
ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
kV
kV
kV
±8
±15 (Note 3)
±25
Min. Air Discharge
Operating Temperature
Storage Temperature
T
-40 to +85
-40 to +125
˚C
˚C
OPR
T
-55 to +150
STG
CG0603MLC-
Parameter
Symbol
Unit
3.3LEA
3.3LE
3.3
05LE
5
12LE
24LE
05LEA
12LEA
12
24LEA
Typical Continuous Operating Voltage
Typical Clamping Voltage (Note 1)
Maximum Capacitance @ 1 VRMS 1 MHz
Maximum Leakage Current @ Max. VDC
Typical Trigger Voltage (Note 2)
V
12
24
3.3
5
24
V
V
DC
V
25
25
25
5
C
O
L
C
0.5
1
pF
nA
V
I
5
5
V
250
250
250
T
T
Maximum Response Time
R
ns
ESD Protection:
Per IEC 61000-4-2 Level 4
Min. Contact Discharge
Min. Air Discharge
kV
kV
kV
±8
±15 (Note 3)
±25
Min. Air Discharge
Operating Temperature
Storage Temperature
T
-40 to +85
-40 to +125
˚C
˚C
OPR
T
-55 to +150
STG
Notes: 1. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement 30 ns after initiation of pulse.
2. Per IEC 61000-4-2, Level 4 8 kV Contact Discharge. Measurement at maximum pulse voltage.
3. IEC 61000-4-2 ESD Performance will meet minimum 1000 reps without degradation in performance.
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov
*RoHS Directive 2015/863, Mar 31, 2015 and Annex.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.