For more information, please visit the product page.
date 07/21/2017
page 1 of 9
SERIES: CFM-70V │ DESCRIPTION: DC AXIAL FAN
FEATURES
• omniCOOLTM bearing system
• 70 x 70 mm frame
• multiple speed options for different cooling needs
• tachometer signal and rotation detect options available
• auto restart protection standard on all models
input
voltage
input
input
rated
air
static
noise4
MODEL
current1
power1
speed1
flow2
pressure3
rated
range
max
max
typ
max
(Vdc)
(Vdc)
(mA)
(W)
(RPM±15%)
(CFM)
19.0
23.0
27.0
23.5
27.0
29.0
37.0
40.0
43.0
23.5
27.0
29.0
(inch H2O)
0.07
0.09
0.11
0.09
0.12
0.14
0.21
0.24
0.28
0.09
0.12
0.14
(dBA)
CFM-7015V-123-215
CFM-7015V-128-265
CFM-7015V-133-315
CFM-7020V-126-260
CFM-7020V-129-300
CFM-7020V-132-330
CFM-7020V-140-375
CFM-7020V-143-400
CFM-7020V-146-415
CFM-7020V-226-360
CFM-7020V-229-300
CFM-7020V-232-330
12
12
12
12
12
12
12
12
12
24
24
24
6.0~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
6.0~13.8
6.0~13.8
6.0~12.6
8.0~27.6
8.0~27.6
8.0~27.6
55
86
0.66
1.04
1.56
1.07
1.37
1.80
2.70
3.18
3.94
1.23
1.54
1.83
2300
2800
3300
26005
29005
32005
4000
4300
4600
26005
29005
32005
21.5
26.5
31.5
26.0
30.0
33.0
37.5
40.0
41.5
26.0
30.0
33.0
130
89
114
150
225
265
328
51
64
76
Notes:
1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
5. Typical rated speed is measured as RPM±10% at rated voltage.
6. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
PART NUMBER KEY
CFM-7015V-123-215 - XX - CXX
Fan Signals
“blank” = no signals
11 = rotation detector signal
20 = tachometer signal
Base Number
Reserved for Custom
Configurations
cui.com