Catalog: 1654986
Issue Date: 06.2011
Corcom Facility EMI Filters Product Guide
CDEUL Series - Extended Range Buffer Networks (Inductive Input)
CDEUL Series
Filter Cabinet
60 Hz Models Only
• Modified NEMA I, constructed of not less than #14
gauge CRS with galvanized bulkhead
• Blue epoxy finish to all non-conductive surfaces
• R.F. Radiation of the shielded (load) compartment
greater than 100 dB from 14 kHz to 10 GHz
• Front cover access, dual cover design
• Filter inserts pre-wired to standoffs and lugs
• Lifting hooks and mounting tabs
• Legs for floor mount available (see page 24)
Individual Filters
• Sealed components with welded and/or soldered
seams
• Constructed of not less than #16 gauge steel with
corrosion resistant plating
• Bleeder resistor to eliminate shock hazard provided
• HEMP Surge arrestors provided upon request‡
Electrical Characteristics
Voltage Drop:
Less than 1% @ unity power factor
Overload:
140% of rated current for 15 minutes
Harmonic Distortion:
Less than 2% @ full rated current
Dielectric Withstanding Voltage:
Per MIL-PRF-15733 and UL1283
D.C. Insulation Resistance:
Per MIL-STD-202, Method 302
Terminal Strength:
Per MIL-STD-202, Method 211, Condition E
Temperature Rise:
Shown with optional legs
Center mounting bracket not installed on all sizes
Per MIL-PRF-15733 and UL1283
R.F. Radiation:
How to Order:
100 dB minimum shielding effectiveness
CDEUL 4 01000 A6 -S -L
Insertion Loss:
Legs
1
Surge Arrestors (optional)
100 dB from 14 kHz - 10 GHz per MIL-STD-220A, under
load condition, using extended range buffer networks
over the frequency range of 14 kHZ - 20 MHz
Voltage/Frequency
A6 - 120/208V, 60Hz
B6 - 277/480V, 60Hz
A4 - 120/208V, 400Hz
Current Rating 2
# of Filtered Phases
Series
Applicable Publications:
MIL-PRF-15733 — Filters, radio interference
MIL-STD-202 — Test methods for Components
MIL-STD-220A — Test method of Insertion Loss
MIL-STD-188-125 — HEMP
Examples:
CDEUL401000A6-S-L =
4, 1000A CDEUL, 120/280V filters in cabinet
with surge arrestors and legs
MIL-STD-285 — Test method for Shielding Effectiveness
NFPA 70-1987 — National Electric Code
486A - 1983 — Wire Connectors and Lug
UL1283 — UL standard for EMI Filters
CDEUL300030B6 =
3, 30A CDEUL, 277/480V filters in cabinet
Note 1:
Note 2:
Surge Arrestor for A6/A4* Models: V251BA60
Surge Arrestor for B6 Models: V481BA60
Current configuration listed as 5 digits with leading zeros
‡ Intended for HEMP applications <150A. For filters rated >225A refer
to the new TECUL Series on page 14.
12
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric
equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
USA Cust. Svc.:
Corcom Prods:
1-800-468-2023
1-847-680-7400
te.com
corcom.com