200/250 Watts
xppower.com
CCB200/250 Series
• 200 & 250 W Convection Cooled
• Very Low Heat Loss
• +70 °C Full Power Operation (CCB200)
• Very High Efficiency up to 95%
• 5 V Standby, Inhibit & Power Fail Signals
• IT & Medical (BF) Safety Approvals
• 3 Year Warranty
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• See derating curve
• 47-63 Hz
• 1.8/2.4 A typical at 115 VAC, full load
(CCB200/250)
0.9/1.2 A typical at 230 VAC, full load
(CCB200/250)
Efficiency
Isolation
• Up to 95%
• 4000 VAC Input to Output 2 x MOPP,
1500 VAC Input to Ground 1 x MOPP,
1500 VAC Output to Ground 1 x MOPP
• See longform datasheet
• Power Fail
Inhibit, 5 V Standby
Switching Frequency
Signals
Inrush Current
Power Factor
• 30 A typical at 230VAC, cold start at 25 °C
• >0.9
MTBF
• 369/230 kHrs to MIL-HDBK-217F at
25 °C, GB (CCB250/200)
Earth Leakage Current • 250 µA max at 264 VAC/60 Hz
No Load Input Power • <0.5 W when inhibit used (CCB200)
Patient Leakage Current • 100 µA max, 264 VAC 60 Hz
Environmental
Operating Temperature • See derating curve & longform datasheet
Cooling
Input Protection
• Internal T5.0 A/250 V fuse in line
and neutral
• Convection cooled
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 95% RH, non-condensing
• -40 °C to +85 °C
• 3048 m for CCB250, 5000 m for CCB200
Output
Output Voltage
Output Voltage Trim
• 12-48 VDC (see tables)
•
3% CCB250, 5% CCB200
(See Mechanical Details)
•
3 x 30g shocks in each plane, total 18
shocks. 30g = 11ms ( 0.5 ms), half sine,
conforms to EN60068-2-27 & EN60068-2-47
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
•
0.5% V1, 5% V2
Vibration
• Single axis 10 - 500 Hz at 2g sweep and
endurance at resonance in all 3 planes.
Conforms to EN60068-2-6
• No minimum load required
• 1 s typical
• 0.5 s typical
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• 16/20 ms min at 90 VAC (CCB250/200)
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1% V1, 5% V2
• EN55011/22 level B conducted
EN55011/22 level A radiated,
See longform datasheet for level A
• EN61000-3-2, class A, >140w class C
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
• IEC60950-1 CB report, UL60950-1, TUV
EN60950-1, IEC60601-1 CB report,
UL60601-1, TUV 60601-1,
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
• 5% max
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Surge
Overvoltage Protection • 115-140% Vnom, recycle input to reset (V1
only)
Conducted Immunity
Dips & Interruptions
Overload Protection
• 125-165% Inom V1 (CCB250), 110 - 150%
Inom V1 (CCB200)
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
Remote On/Off
(Inhibit/Enable)
• 0.05%/°C
• Uncommitted isolated optocoupler diode,
powered diode inhibits V1
Safety Approvals
Equipment Protection • EN60601-1, ANSI/AAMI ES60601-1,
Class
CSA22.2 No.60601-1 per cUL BF Rated,
Including Risk Management, EN60950,
UL60950